{"data":{"id":"us/46-cfr-111.107-1","jurisdiction":"us","citation":"46 CFR 111.107-1","heading":"-1 Industrial systems.","body":"(a) For the purpose of this subpart, an industrial system is a system that—\n(1) Is not a ship's service load, as defined in § 110.15-1;\n(2) Is used only for the industrial function of the vessel;\n(3) Is not connected to the emergency power source; and\n(4) Does not have specific requirements addressed elsewhere in this subchapter.\n(b) An industrial system that meets the applicable requirements of NFPA 70 (incorporated by reference; see § 110.10-1 of this subchapter) must meet only the following:\n(1) Part 110, subpart 110.25, of this chapter—Plan Submittal.\n(2) Subpart 111.01 of this part—General.\n(3) Subpart 111.05 of this part—Equipment Ground, Ground Detection, and Grounded Systems.\n(4) Sections 111.12-1(b) and 111.12-1(c)—Prime movers.\n(5) Sections 111.30-1, 111.30-5(a), and 111.30-19(a)—Switchgear.\n(6) Subpart 111.105 of this part—Hazardous Locations.\n(c) Cables that penetrate a watertight or fire boundary deck or bulkhead must—\n(1) Be installed in accordance with 46 CFR 111.60-5 and meet the flammability-test requirements of either IEEE 1202, IEC 60332-3-22:2018, or IEC 60332-3-21:2018, Category A or A F/R (all incorporated by reference; see § 110.10-1 of this subchapter); or\n(2) Be specialty cable installed in accordance with § 111.60-2.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER J—ELECTRICAL ENGINEERING","PART 111—ELECTRIC SYSTEMS—GENERAL REQUIREMENTS","Subpart 111.107—Industrial Systems"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"1151106dae5eec1f4c9b0b925e7fa90d289a54c2e20f1ed16fb351f9aa583924","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-111.106-17","next":"us/46-cfr-111.108-1"},"notice":"GroundRules: Original legal text. Not legal advice."}