{"data":{"id":"us/46-cfr-111.30-24","jurisdiction":"us","citation":"46 CFR 111.30-24","heading":"-24 Generation systems greater than 3000 kW.","body":"Except on a non-self-propelled mobile offshore drilling unit (MODU) and a non-self-propelled floating Outer Continental Shelf facility, when the total installed electric power of the ship's service generation system is more than 3000 kW, the switchboard must have the following:\n(a) At least two sections of the main bus that are connected by:\n(1) A non-automatic circuit breaker;\n(2) A disconnect switch; or\n(3) Removable links.\n(b) As far as practicable, the connection of generators and duplicated equipment equalized between the sections of the main bus.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER J—ELECTRICAL ENGINEERING","PART 111—ELECTRIC SYSTEMS—GENERAL REQUIREMENTS","Subpart 111.30—Switchboards"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"0389a76dbda6b6663dfc79a7dc44b2f0f60cf77e5b27898a40973b5414f7cee6","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-111.30-19","next":"us/46-cfr-111.30-25"},"notice":"GroundRules: Original legal text. Not legal advice."}