{"data":{"id":"us/46-cfr-111.30-3","jurisdiction":"us","citation":"46 CFR 111.30-3","heading":"-3 Accessibility of switchboard components and connections.","body":"Each component and bus bar connection on a switchboard that is not accessible from the rear, except a bus bar connection for a draw-out type circuit breaker, must be within 0.5 m (20 in.) of the front of the switchboard.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER J—ELECTRICAL ENGINEERING","PART 111—ELECTRIC SYSTEMS—GENERAL REQUIREMENTS","Subpart 111.30—Switchboards"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"3e871b7ed272273ff4fde3f3d53a261c12a66f33cc592ad9eb114a8a69628d7e","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-111.30-1","next":"us/46-cfr-111.30-4"},"notice":"GroundRules: Original legal text. Not legal advice."}