{"data":{"id":"us/46-cfr-120.360","jurisdiction":"us","citation":"46 CFR 120.360","heading":"Semiconductor rectifier systems.","body":"(a) Each semiconductor rectifier system must have an adequate heat removal system that prevents overheating.\n(b) Where a semiconductor rectifier system is used in a propulsion system or in other vital systems it must:\n(1) Have a current limiting circuit;\n(2) Have external overcurrent protection; and\n(3) Meet Sections 35.84.2 and 35.84.4 of the American Bureau of Shipping (ABS), “Rules for Building and Classing Steel Vessels,” or other standard specified by the Commandant.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER K—SMALL PASSENGER VESSELS CARRYING MORE THAN 150 PASSENGERS OR WITH OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS","PART 120—ELECTRICAL INSTALLATION","Subpart C—Power Sources and Distribution Systems"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"6ada90e6908a585b71dff4359a000930212f5efb3dbacfe31f71ec5bfb62d228","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-120.354","next":"us/46-cfr-120.370"},"notice":"GroundRules: Original legal text. Not legal advice."}