{"data":{"id":"us/46-cfr-133.120","jurisdiction":"us","citation":"46 CFR 133.120","heading":"Launching stations.","body":"(a) Each launching station must be positioned to ensure safe launching with clearance from—\n(1) The propeller; and\n(2) The steeply overhanging portions of the hull.\n(b) Each survival craft must be launched down the straight side of the OSV.\n(c) Each launching station in the forward part of the OSV must—\n(1) Be located aft of the collision bulkhead in a sheltered position; and\n(2) Have a launching appliance approved as being of sufficient strength for forward installation.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER L—OFFSHORE SUPPLY VESSELS","PART 133—LIFESAVING SYSTEMS","Subpart B—Requirements for All OSVs"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"1584aa2ec63a7541373a654db846a195f011267b7aa4f2e316e64cbfe3d91a43","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-133.110","next":"us/46-cfr-133.130"},"notice":"GroundRules: Original legal text. Not legal advice."}