{"data":{"id":"us/46-cfr-153.1000","jurisdiction":"us","citation":"46 CFR 153.1000","heading":"Special operating requirements for cargoes reactive with water.","body":"When Table 1 refers to this section, the master must ensure that the cargo:\n(a) Is carried only in a containment system completely isolated from any systems containing water, such as slop tanks, ballast tanks, cargo tanks containing slops or ballast, their vent lines or piping; and\n(b) Is separated by double walls, such as cofferdams and piping tunnels, from any system containing water, as for example those described in paragraph (a) of this section.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER O—CERTAIN BULK DANGEROUS CARGOES","PART 153—SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS","Subpart C—Operations"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"b9b8c3fadfdecfc76caa4e01ef6cfebe53a26adee5f9136303738b45474c4924","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-153.983","next":"us/46-cfr-153.1002"},"notice":"GroundRules: Original legal text. Not legal advice."}