{"data":{"id":"us/46-cfr-154.1005","jurisdiction":"us","citation":"46 CFR 154.1005","heading":"Equipment approval.","body":"(a) Electrical equipment that is required to be intrinsically safe or explosion proof under § 154.1010 must be specially approved by the Commandant or listed as intrinsically safe or explosion proof by an independent laboratory that is specially approved by the Commandant (CG-OES), for Class I Division I locations and the Group that is specified in Table 4 for the cargo carried.\n(b) Each submerged cargo pump motor installation must be specially approved by the Commandant (CG-OES).\n(c) Electrical equipment that must be intrinsically safe to meet § 154.1010 must meet the definition in § 110.15-100(i) of this chapter.\n(d) Electrical equipment that must be explosion proof to meet § 154.1010 must meet § 110.15-65(e) of this chapter.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER O—CERTAIN BULK DANGEROUS CARGOES","PART 154—SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES","Subpart C—Design, Construction and Equipment"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"2fa88e5d11ca4c32c1f32293d2cccf40e476e4a66b44f3df7795f36faefb2330","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-154.1002","next":"us/46-cfr-154.1010"},"notice":"GroundRules: Original legal text. Not legal advice."}