{"data":{"id":"us/46-cfr-154.1015","jurisdiction":"us","citation":"46 CFR 154.1015","heading":"Lighting in gas-dangerous space.","body":"(a) Each gas-dangerous space that has lighting fixtures must have at least two branch circuits for lighting.\n(b) Each switch and each overcurrent protective device for any lighting circuit that is in a gas-dangerous space must open each conductor of the circuit simultaneously.\n(c) Each switch and each overcurrent protective device for lighting in a gas-dangerous space must be in a gas-safe space.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER O—CERTAIN BULK DANGEROUS CARGOES","PART 154—SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES","Subpart C—Design, Construction and Equipment"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"000674773df658822a28d96d48f8061f8ce8b4ada11228ae3e6adf01ec23b6fb","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-154.1010","next":"us/46-cfr-154.1020"},"notice":"GroundRules: Original legal text. Not legal advice."}