{"data":{"id":"us/46-cfr-154.1130","jurisdiction":"us","citation":"46 CFR 154.1130","heading":"Sections.","body":"(a) If a water spray system is divided into sections, each section must at least include the entire deck area bounded by the length of a cargo tank and the full beam of the vessel.\n(b) If a water spray system is divided into sections, the control valves must be at a single manifold that is aft of the cargo area.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER O—CERTAIN BULK DANGEROUS CARGOES","PART 154—SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES","Subpart C—Design, Construction and Equipment"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"8e67438f5122acf8dfda05735e708aad81ef6e263abf367945bce78d5bdc4cd2","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-154.1125","next":"us/46-cfr-154.1135"},"notice":"GroundRules: Original legal text. Not legal advice."}