{"data":{"id":"us/46-cfr-154.1200","jurisdiction":"us","citation":"46 CFR 154.1200","heading":"Mechanical ventilation system: General.","body":"(a) Each cargo compressor room, pump room, gas-dangerous cargo control station, and space that contains cargo handling equipment must have a fixed, exhaust-type mechanical ventilation system.\n(b) The following must have a supply-type mechanical ventilation system:\n(1) Each space that contains electric motors for cargo handling equipment.\n(2) Each gas-safe cargo control station in the cargo area.\n(3) Each gas-safe space in the cargo area.\n(4) Each space that contains inert gas generators, except main machinery spaces.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER O—CERTAIN BULK DANGEROUS CARGOES","PART 154—SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES","Subpart C—Design, Construction and Equipment"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"40e802d4536929a48e6f8a0bcc6eac18052b4ee69ec8e5ad88fd49463eb90034","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-154.1170","next":"us/46-cfr-154.1205"},"notice":"GroundRules: Original legal text. Not legal advice."}