{"data":{"id":"us/46-cfr-154.325","jurisdiction":"us","citation":"46 CFR 154.325","heading":"Accommodation, service, and control spaces.","body":"(a) Accommodation, service, and control spaces must be outside the cargo area.\n(b) If a hold space having a cargo containment system, required by this part to have a secondary barrier, is separated from any accommodation, service, or control space by a cruciform joint, there must be a cofferdam providing at least 760 mm (30 inches) by 760 mm (30 inches) clearance on one side of the cruciform joint.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER O—CERTAIN BULK DANGEROUS CARGOES","PART 154—SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES","Subpart C—Design, Construction and Equipment"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"2f08aab0392f17134f1438b97d3002b95fa47e3d5152b5c6e01d315be959a89b","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-154.320","next":"us/46-cfr-154.330"},"notice":"GroundRules: Original legal text. Not legal advice."}