{"data":{"id":"us/46-cfr-154.705","jurisdiction":"us","citation":"46 CFR 154.705","heading":"Cargo boil-off as fuel: General.","body":"(a) Each cargo boil-off fuel system under § 154.703(c) must meet §§ 154.706 through 154.709.\n(b) The piping in the cargo boil-off fuel system must have a connection for introducing inert gas and for gas freeing the piping in the machinery space.\n(c) A gas fired main propulsion boiler or combustion engine must have a fuel oil fired pilot that maintains fuel flow as required under § 154.1854 if the gas fuel supply is cut-off.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER O—CERTAIN BULK DANGEROUS CARGOES","PART 154—SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES","Subpart C—Design, Construction and Equipment"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"93f4fbc089a8e0f34936a1647e1469b236a55b6913034aa48dbf7266953e348a","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-154.703","next":"us/46-cfr-154.706"},"notice":"GroundRules: Original legal text. Not legal advice."}