{"data":{"id":"us/46-cfr-154.906","jurisdiction":"us","citation":"46 CFR 154.906","heading":"Inert gas generators.","body":"The inert gas generator must:\n(a) Produce an inert gas containing less than 5% oxygen by volume;\n(b) Have a device to continuously sample the discharge of the generator for oxygen content; and\n(c) Have an audible and visual alarm in the cargo control station that alarms when the inert gas contains 5% or more oxygen by volume.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER O—CERTAIN BULK DANGEROUS CARGOES","PART 154—SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES","Subpart C—Design, Construction and Equipment"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"832172764bb50c0a86eedf31ade0a9e5d255c1c1713a6829ceaaba4a6dd668a8","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-154.904","next":"us/46-cfr-154.908"},"notice":"GroundRules: Original legal text. Not legal advice."}