{"data":{"id":"us/46-cfr-162.050-19","jurisdiction":"us","citation":"46 CFR 162.050-19","heading":"-19 Oil content meter and bilge alarm test rig.","body":"(a) This section contains requirements for test rigs used in approval testing of oil content meters and meter. A typical test rig is described in Figure 162.050-19. The mixture pipe shown in Figure 162.050-19 is the portion of test rig piping between the oil injection point and the meter or bilge alarm piping.\n(b) Each sample point on a test rig must be of the type described in Figure 162.050-17(e) and must be in a vertical portion of the test rig piping.\n(c) Each test rig must have a centrifugal pump that is designed to operate at 1,000 revolutions per minute or more.\n(d) The mixture pipe on a test rig must have a uniform inside diameter.\nFIGURE 162.050-19—MONITOR AND BILGE ALARM TEST RIG","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER Q—EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL","PART 162—ENGINEERING EQUIPMENT","Subpart 162.050—Pollution Prevention Equipment"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"e9ae5d49daa453221fa833f277823d48a04736c8c945a69cf1edd0b61e1e879d","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-162.050-17","next":"us/46-cfr-162.050-20"},"notice":"GroundRules: Original legal text. Not legal advice."}