{"data":{"id":"us/46-cfr-183.354","jurisdiction":"us","citation":"46 CFR 183.354","heading":"Battery installations.","body":"(a) Large batteries. Each large battery installation must be located in a locker, room or enclosed box solely dedicated to the storage of batteries. Ventilation must be provided in accordance with § 111.15-10 in subchapter J of this chapter. Electrical equipment located within the battery enclosure must be approved by an independent laboratory for Class I, Division 1, Group B hazardous locations and meet § 111.105 in subchapter J of this chapter.\n(b) Small batteries. Each small battery installation must be located in a well ventilated space and protected from falling objects. A small battery installation must not be in a closet, storeroom or similar space.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER T—SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS)","PART 183—ELECTRICAL INSTALLATION","Subpart C—Power Sources and Distribution Systems"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"5a29a72bab2516b2d9c72fa2635616a8292e6f60bd0bad42c337c97559584f1b","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-183.352","next":"us/46-cfr-183.360"},"notice":"GroundRules: Original legal text. Not legal advice."}