{"data":{"id":"us/46-cfr-28.250","jurisdiction":"us","citation":"46 CFR 28.250","heading":"High water alarms.","body":"On a vessel 36 feet (11.8 meters) or more in length, a visual and audible alarm must be provided at the operating station to indicate high water level in each of the following normally unmanned spaces:\n(a) A space with a through-hull fitting below the deepest load waterline, such as the lazarette;\n(b) A machinery space bilge, bilge well, shaft alley bilge, or other space subject to flooding from sea water piping within the space; and\n(c) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER C—UNINSPECTED VESSELS","PART 28—REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS","Subpart C—Requirements for Documented Vessels That Operate Beyond the Boundary Lines or With More Than 16 Individuals On Board, or for Fish Tender Vessels Engaged in the Aleutian Trade"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"1c7d86b4c6b6bfc997476bd4414f320eaa643a018391e9d7094cbc35ff922565","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-28.245","next":"us/46-cfr-28.255"},"notice":"GroundRules: Original legal text. Not legal advice."}