{"data":{"id":"us/46-cfr-45.63","jurisdiction":"us","citation":"46 CFR 45.63","heading":"Correction for sheer.","body":"(a) The minimum summer freeboard must be increased by the deficiency, or may be decreased by the excess as limited by § 45.65, of sheer calculated from table 4, multiplied by:\n0.75—(S/2L)\nwhere S is the total length of enclosed superstructures. Trunks are not included.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER E—LOAD LINES","PART 45—GREAT LAKES LOAD LINES","Subpart C—Freeboards"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"6be9d001644b138c89316a881f5c9d433ee54252801bd5d2b05c28dcf5a91b5c","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-45.61","next":"us/46-cfr-45.65"},"notice":"GroundRules: Original legal text. Not legal advice."}