{"data":{"id":"us/46-cfr-64.93","jurisdiction":"us","citation":"46 CFR 64.93","heading":"Pump controls.","body":"(a) A pressure gauge must be installed—\n(1) On the pump discharge;\n(2) Near the pump controls; and\n(3) Visible to the operator.\n(b) A pump must have a remote, quick acting, manual shutdown that is conspicuously labeled and located in an easily accessible area away from the pump. The quick acting, manual shutdown for remote operation must provide a means of stopping the pump power unit.","path":["Title 46—Shipping","CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY","SUBCHAPTER F—MARINE ENGINEERING","PART 64—MARINE PORTABLE TANKS AND CARGO HANDLING SYSTEMS","Subpart F—Cargo Handling System"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-46.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:22Z","sha256":"a1cbb28229ca8a0e8eb82537f2d5e6ad9745344492274ec13684393d24ae9514","source_id":"us-cfr","stale":true,"prev":"us/46-cfr-64.91","next":"us/46-cfr-64.95"},"notice":"GroundRules: Original legal text. Not legal advice."}