{"data":{"id":"us/49-cfr-192.1003","jurisdiction":"us","citation":"49 CFR 192.1003","heading":"What do the regulations in this subpart cover?","body":"(a) General. Unless exempted in paragraph (b) of this section, this subpart prescribes minimum requirements for an IM program for any gas distribution pipeline covered under this part, including liquefied petroleum gas systems. A gas distribution operator must follow the requirements in this subpart.\n(b) Exceptions. This subpart does not apply to:\n(1) Individual service lines directly connected to a production line or a gathering line other than a regulated onshore gathering line as determined in § 192.8;\n(2) Individual service lines directly connected to either a transmission or regulated gathering pipeline and maintained in accordance with § 192.740(a) and (b); and\n(3) Master meter systems.","path":["Title 49—Transportation","Subtitle B—Other Regulations Relating to Transportation","CHAPTER I—PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION","SUBCHAPTER D—PIPELINE SAFETY","PART 192—TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS","Subpart P—Gas Distribution Pipeline Integrity Management (IM)"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-49.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:34Z","sha256":"f4ac81c2196402b62d6e7d59694227209e2e55863ceb10c30eea037a87d25f71","source_id":"us-cfr","stale":true,"prev":"us/49-cfr-192.1001","next":"us/49-cfr-192.1005"},"notice":"GroundRules: Original legal text. Not legal advice."}