{"data":{"id":"us/49-cfr-195.124","jurisdiction":"us","citation":"49 CFR 195.124","heading":"Closures.","body":"Each closure to be installed in a pipeline system must comply with the 2007 ASME Boiler and Pressure Vessel Code (BPVC) (Section VIII, Division 1) (incorporated by reference, see § 195.3) and must have pressure and temperature ratings at least equal to those of the pipe to which the closure is attached.","path":["Title 49—Transportation","Subtitle B—Other Regulations Relating to Transportation","CHAPTER I—PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION","SUBCHAPTER D—PIPELINE SAFETY","PART 195—TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE","Subpart C—Design Requirements"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-49.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:34Z","sha256":"56b3d2ce2fefe81d4497748f43a6e7c0c3847cc29470d2770a2f089487f7e125","source_id":"us-cfr","stale":true,"prev":"us/49-cfr-195.122","next":"us/49-cfr-195.126"},"notice":"GroundRules: Original legal text. Not legal advice."}