{"data":{"id":"us/49-cfr-195.583","jurisdiction":"us","citation":"49 CFR 195.583","heading":"What must I do to monitor atmospheric corrosion control?","body":"(a) You must inspect each pipeline or portion of pipeline that is exposed to the atmosphere for evidence of atmospheric corrosion, as follows:\nIf the pipeline is located: Then the frequency of inspection is:\nOnshore At least once every 3 calendar years, but with intervals not exceeding 39 months.\nOffshore At least once each calendar year, but with intervals not exceeding 15 months.\n(b) During inspections you must give particular attention to pipe at soil-to-air interfaces, under thermal insulation, under disbonded coatings, at pipe supports, in splash zones, at deck penetrations, and in spans over water.\n(c) If you find atmospheric corrosion during an inspection, you must provide protection against the corrosion as required by § 195.581.","path":["Title 49—Transportation","Subtitle B—Other Regulations Relating to Transportation","CHAPTER I—PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION","SUBCHAPTER D—PIPELINE SAFETY","PART 195—TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE","Subpart H—Corrosion Control"],"source_url":"https://www.ecfr.gov/api/versioner/v1/full/2026-08-25/title-49.xml","current_through":"2026-08-25","vintage":"","retrieved_at":"2026-08-27T02:26:34Z","sha256":"e90ad27b10a68a2d4fde8c45577edf712b4786f00875a4587d5686fe5854e9d4","source_id":"us-cfr","stale":true,"prev":"us/49-cfr-195.581","next":"us/49-cfr-195.585"},"notice":"GroundRules: Original legal text. Not legal advice."}