N.Y. Labor Law § 274: Fire-escapes erected before October first, nineteen hundred and thirteen

Read at publisher ↗
Where this section sits in the code
  1. Labor Law
  2. Article 11. Factories
  3. Title 3. Fire Hazard

§ 274. Fire-escapes erected before October first, nineteen hundred and

thirteen. All outside fire-escapes erected before October first,

nineteen hundred and thirteen, and serving as required exits under the

provisions of section two hundred and seventy-one shall conform to the

following requirements:

1. There shall be balconies on each floor of the building connected

with stairways placed at an angle of not more than sixty degrees.

2. A stairway shall lead from the top floor balcony to the roof,

except when the fire-escapes are erected on the front of the building.

3. A stairway not less than twenty-two inches wide shall lead from the

lowest balcony to a safe landing place beneath, which stairway shall

remain down permanently or swing up and down by counterbalancing

weights.

4. A safe and unobstructed exit shall be provided to the street from

the foot of such fire-escapes as required in subdivision nine of section

two hundred and seventy-three.

5. Steps shall connect the sill of every opening leading to the

fire-escapes with the floor wherever such sill is more than three feet

above the floor level.

6. All openings leading to the fire-escapes shall be provided with

fireproof windows or fire doors.

7. All windows opening upon the course of the fire-escape shall be

fireproof windows.