N.Y. Labor Law § 274: Fire-escapes erected before October first, nineteen hundred and thirteen
Where this section sits in the code
- Labor Law
- Article 11. Factories
- Title 3. Fire Hazard
§ 274. Fire-escapes erected before October first, nineteen hundred and
thirteen. All outside fire-escapes erected before October first,
nineteen hundred and thirteen, and serving as required exits under the
provisions of section two hundred and seventy-one shall conform to the
following requirements:
1. There shall be balconies on each floor of the building connected
with stairways placed at an angle of not more than sixty degrees.
2. A stairway shall lead from the top floor balcony to the roof,
except when the fire-escapes are erected on the front of the building.
3. A stairway not less than twenty-two inches wide shall lead from the
lowest balcony to a safe landing place beneath, which stairway shall
remain down permanently or swing up and down by counterbalancing
weights.
4. A safe and unobstructed exit shall be provided to the street from
the foot of such fire-escapes as required in subdivision nine of section
two hundred and seventy-three.
5. Steps shall connect the sill of every opening leading to the
fire-escapes with the floor wherever such sill is more than three feet
above the floor level.
6. All openings leading to the fire-escapes shall be provided with
fireproof windows or fire doors.
7. All windows opening upon the course of the fire-escape shall be
fireproof windows.