GroundRules
← Search the law
New York · Through 2026-09-11

N.Y. Multiple Dwelling Law § 146: Egress from apartments

Read at publisher ↗
Where this section sits in the code
  1. Multiple Dwelling Law
  2. Article 5. Non-fireproof Multiple Dwellings
  3. Title 1. Fire Protection

§ 146. Egress from apartments. 1. There shall be at least two means of

egress from every apartment or suite. Such means shall be remote from

each other. Except where it opens into a stair as permitted in

subdivision three, one means shall be to a public hall connecting with a

stair, fire-stair or fire-tower, not more than fifty feet distant from

such means. In dwellings erected under plans filed in the department

after September first, nineteen hundred fifty-one, such stair,

fire-stair or fire-tower shall be enclosed. The other required means of

egress shall open either directly upon a fire-escape or directly on a

fire-tower balcony or a public vestibule or other public hall connecting

with a stair, fire-stair or fire-tower balcony.

2. Except as hereinafter provided for dwellings two stories or less in

height such balcony, vestibule, hall or stair shall be separated from

the public hall or stair on which the first means of egress opens by a

fireproof wall, unpierced unless by an opening equipped with a fireproof

door and assembly with the door self-closing. Such door shall not be

held open by any device whatever. In a dwelling two stories or less in

height, the separating wall may be fire-retarded on both sides in lieu

of being fireproof.

3. In a dwelling three stories or less in height and occupied by four

families or less on each story, and in any section of a class A dwelling

which is two stories or less in height and occupied by four families or

less on each story, a means of egress from an apartment may open

directly into a stair without the intervention of a public hall.