N.Y. Multiple Dwelling Law § 240: First tier of beams

Read at publisher ↗
Where this section sits in the code
  1. Multiple Dwelling Law
  2. Article 7. Tenements
  3. Title 2. Fire Protection

§ 240. First tier of beams. 1. In all tenements erected after April

twelfth, nineteen hundred one, which are five stories or more in height,

the first floor above the lowest cellar, or, if there be no cellar,

above the basement or other lowest story, shall be fireproof; and all

exposed portions of any iron or steel beams below the floor arches shall

be fire-retarded.

2. In all non-fireproof tenements erected after such date which are

four stories or less in height, the ceiling of the lowest cellar, or, if

there be no cellar, of the basement or other lowest story, shall be

fire-retarded or covered with plaster boards at least one-half inch in

thickness, with all joints made true and well pointed.

3. In all old-law tenements which are four stories or more in height

the ceiling of the cellar, or, if there be no cellar, of the basement or

other lowest story, shall be fire-retarded.