N.Y. Multiple Residence Law § 57: Vertical and horizontal openings

Read at publisher ↗
Where this section sits in the code
  1. Multiple Residence Law
  2. Article 4. Hotels and Similar Dwellings
  3. Title 1. Fire Protection

§ 57. Vertical and horizontal openings. In order to prevent the

vertical and horizontal spread of fire, smoke and gases, it shall, in

addition to other applicable provisions of this article, be necessary to

comply with the requirements of this section.

1. All doors opening from shafts, stair halls or stairs and the door

assemblies shall be fire-retarded with the doors self-closing and

without transoms or any other opening. Except in the case of elevator

shafts, such shafts, stair halls or stairs may be protected by an

automatic sprinkler system in lieu of fire retarding.

2. All other doors opening upon entrance halls or other public halls

or corridors in every part of the dwelling shall be self-closing, except

where such dwelling is equipped throughout with an approved type

automatic sprinkler or fire-detecting system. It shall be unlawful to

attach to or maintain on or about any door required to be self-closing

any device which prevents the self-closing of such door.

3. Every existing interior glazed sash, window or opening, other than

a door, or a fireproof sash, window or opening glazed with wire glass,

in any partition forming required enclosures around stairs or shafts

shall be removed and the openings closed up and fire-retarded.