N.Y.C. Admin. Code § 27-358: § 27-358 Occupant load.
Where this section sits in the code
- New York City Administrative Code
- Title 27
- Chapter 1: Building Code
The number of occupants for whom exit facilities shall be provided shall be established either (1) by the actual number of occupants for whom each occupied space, floor, or building, as the case may be, is designed, or (2) by using the appropriate occupant-area ratios from table 6-2, whichever is larger. The occupant load of any space shall include the occupant load of all spaces that discharge through it in order to gain access to an exit.
TABLE 6-2 Occupant Load Requirements Net Area Table
Occupancy
Net Floor Area per Occupant (sq. ft.)
Billiard rooms
50
Bowling alleys
50
Classrooms
20
Dance floors
10
Dining spaces (nonresidential)
12
Exhibition spaces
10
Garages and open parking structures
250
Gymnasiums
15
Habitable rooms
140
Industrial shops
200
In schools
30
Institutional sleeping rooms
Adults
75
Children (except as listed below)
50
Day Care
a. under 6 mos.
50
b. 6 mos. 2 yrs.
40
c. 2 yrs. 6 yrs.
30
Institutional staff, all
30
Kindergartens
35
Kitchens (nonresidential)
200
Laboratories
50
Preparation rooms
100
Libraries
25
Locker rooms
12
Offices
100
Passenger terminals or platforms
1.5xC
Sales areas (retail)
1st floor or basement
25
All other floors
50
Seating areas (audience) in all places of assembly
Fixed seats
D
Moveable seats
10
Skating rinks
15
Stages (See subchapter eight)
Standing room (audience) in all places of assembly
4
Storage rooms
200
Notes: C – capacity of all passenger vehicles that can be unloaded simultaneously. D – designed number of seats or occupants.
(a) Unlisted occupancies. Where data regarding the sq. ft. per person for an occupancy is not listed in table 6-2, the occupant load shall be established by an architect or engineer, subject to the approval of the commissioner.
(b) Modifications.
(1) When the actual occupant load of any space will be significantly lower than that listed in table 6-2, the commissioner may establish a lower basis for the determination of the occupant load.
(2) When a building existing on December sixth, nineteen hundred sixty-eight is altered or changed in occupancy or use so as to require enlarged exit facilities, the commissioner may authorize the alteration or change in occupancy or use without an enlargement of exit facilities, provided the occupant load is limited to that accommodated by the existing exit facilities as determined by the provisions of this code, and the building or space is posted accordingly with a sign. Such signs shall be at least twelve inches in width and sixteen inches in height. The lettering shall be red on a white background. The letters shall be not less than one inch high and the numerals not less than one and one-quarter inches high.
(c) Nonsimultaneous occupancy. The occupant load of toilets, locker rooms, meeting rooms, storage rooms, employee cafeterias, and similar rooms or spaces that are not occupied at the same time as other rooms or spaces on the same floor of a building, may be omitted from the occupant load calculation of the floor on which they are located to the extent that such spaces serve occupied rooms on the same floor.