1508.1 General.
The use of above-deck thermal insulation shall be permitted provided such insulation is covered with an approved roof covering and passes the tests of NFPA 276 or UL 1256 when tested as an assembly.
Exceptions:
1. Foam plastic roof insulation shall conform to the material and installation requirements of Chapter 26 of this code.
2. Where a concrete roof deck is used and the above-deck thermal insulation is covered with an approved roof covering.
1508.1.1 Cellulosic fiberboard.
Cellulosic fiberboard roof insulation shall conform to the material and installation requirements of Chapter 23.
1508.2 Material standards.
Above-deck thermal insulation board shall comply with the standards in Table 1508.2.
Table 1508.2 Material Standards for Roof Insulation
Material
Standard
Cellular glass board
ASTM C 552
Composite boards
ASTM C 1289, Type III, IV, V or VI
Expanded polystyrene
ASTM C 578
Extruded polystyrene
ASTM C 578
Fiber-reinforced gypsum board
ASTM C 1278
Glass-faced gypsum board
ASTM C 1177
Mineral fiber insulation board
ASTM C 726
Perlite board
ASTM C 728
Polyisocyanurate board
ASTM C 1289, Type I or II
Wood fiberboard
ASTM C 208