A301.1 Purpose.

The provisions of this chapter are intended to reduce the risk of lateral force induced damage to existing wood-frame residential buildings. The requirements in this chapter are prescriptive or schematic minimum standards intended to incrementally improve the lateral force resisting performance of residential buildings. Compliance with these provisions will not necessarily prevent damage due to earthquake, wind, or flood loading.

This chapter includes standards for strengthening that may be approved by the commissioner without requiring submittal of plans or calculations prepared by a registered design professional. The provisions of this chapter are not intended to prevent the use of any material or method of construction not prescribed herein. The commissioner may require that construction documents for strengthening using alternative materials or methods be prepared by a registered design professional.

A301.2 Scope.

Perform prescriptive strengthening and/or repairs of sill connections per Figures A3-1 through A3-3. For framing conditions or materials not shown in these Figures, consult a registered design professional. For strengthening and/or repairing cripple walls, use the recommended schematic information in Figures A3-4 through A3-6 in conjunction with consultation with a registered design professional. If existing sill plates are in poor condition, consult a registered design professional.

Figure A3-1 Missing Sill Plate Anchors to Wall Prescriptive Remidial Connection of Sill Plate

Figure A3-2 Missing Sill Plate Anchors to Wall Alternate Prescriptive Remidial Connection of Sill Plate

Figure A3-3 Missing Anchorage of Framing to Sill Plate Prescriptive Remidial Connection of Framing to Sill Plate

Figure A3-4 Cripple Wall Not Braced by Sheathing Schematic Remedial Bracing of Cripple Wall, With Joists Perpendicular or Parallel to Wall

Figure A3-5 Schematic Floor Plan of Remedial Cripple Wall Bracing Panel Layout

Figure A3-6 Additional Notes to Figure A3-5