N.Y.C. Admin. Code § PC 1502: Section PC 1502: Standards

Read at publisher ↗
Where this section sits in the code
  1. New York City Administrative Code
  2. Title 28
  3. Chapter 6: New York City Plumbing Code

AHRI

Air-Conditioning, Heating, & Refrigeration Institute 4100 North Fairfax Drive, Suite 200 Arlington, VA 22203

Standard reference number

Title

Referenced in code section number

1010—02

Self-contained, Mechanically Refrigerated Drinking-Water Coolers

410.1

810—16 Addendum 1

Performance Rating of Automatic Commercial Ice-makers

428.1.1

ANSI

American National Standards Institute 25 West 43rd Street, Fourth Floor New York, NY 10036

Standard reference number

Title

Referenced in code section number

A118.10—99

Specifications for Load Bearing, Bonded, Waterproof Membranes for Thin Set Ceramic Tile and Dimension Stone Installation

417.5.2.5, 417.5.2.6

Z4.3—95

Minimum Requirements for Nonsewered Waste-disposal Systems

311.1

Z21.22—99 (R2003)

Relief Valves for Hot Water Supply Systems with Addenda Z21.22a—2000 (R2003) and Z21.22b—2001 (R2003)

504.2, 504.4, 504.4.1

CSA B45.5—11 / IAPMO Z124—11

Plastic Plumbing Fixtures

407.1, 415.1, 416.1, 416.2, 417.1, 418.1, 419.1, 420.1

API

American Petroleum Institute 1220 L Street NW Washington, DC 20005-4070

Standard reference number

Title

Referenced in code section number

12D – 2008

Specification for Field Welded Tanks for Storage of Production Liquids, effective April 1, 2009

1302.7.2, 1303.10.2

12F – 2008

Specification for Shop Welded Tanks for Storage of Production Liquids, effective April 1, 2009

1302.7.2, 1303.10.2

ASCE/SEI

American Society of Civil Engineers Structural Engineering Institute 1801 Alexander Bell Drive Reston, VA 20191-4400

Standard reference number

Title

Referenced in code section number

24—14

Flood Resistant Design and Construction

715.1, 1101.9.1

ASME

American Society of Mechanical Engineers Three Park Avenue New York, NY 10016-5990

Standard reference number

Title

Referenced in code section number

A112.1.2—2004

Air Gaps in Plumbing Systems

406.1, 409.2, Table 608.1, 608.13.1

A112.1.3—2000 (R2011)

Air Gap Fittings for Use with Plumbing Fixtures, Appliances and Appurtenances

406.1, 409.2, Table 608.1, 608.13.1

A112.3.1—2007

Stainless Steel Drainage Systems for Sanitary, DWV, Storm and Vacuum Applications Above and Below Ground

412.1, Table 702.1, Table 702.2, Table 702.3, Table 702.4, Table 1102.4, 1102.6, Table 1102.7

A112.3.4—2013 / CSA B45.9—2013

Macerating Toilet Systems and Related Components

712.4.1

A112.4.1—2009

Water Heater Relief Valve Drain Tubes

504.6

A112.4.2—2009

Water Closet Personal Hygiene Devices

424.9

A112.4.3—1999 (R2010)

Plastic Fittings for Connecting Water Closets to the Sanitary Drainage System

405.4

A112.4.14—2004 (R2010)

Manually Operated, Quarter-Turn Shutoff Valves for Use in Plumbing Systems

Table 605.7

A112.6.1M—1997 (R2008)

Floor-affixed Supports for Off-the-floor Plumbing Fixtures for Public Use

405.4.3

A112.6.2—2000 (R2010)

Framing-affixed Supports for Off-the-floor Water Closets with Concealed Tanks

405.4.3

A112.6.3—2001 (R2007)

Floor and Trench Drains

412.1

A112.6.4—2003 (R2008)

Roof, Deck, and Balcony Drains

1102.6

A112.6.7—2010

Enameled and Epoxy-coated Cast-iron and PVC Plastic Sanitary Floor Sinks

427.1

A112.6.9—2005 (R2010)

Siphonic Roof Drains

1107.1

A112.14.1—2003

Backwater Valves

715.2

A112.14.3—2000

Grease Interceptors

1003.3.4

A112.14.4—2001 (Reaffirmed 2007)

Grease Removal Devices

1003.3.4

A112.18.1—2012 / CSA B125.1—2012

Plumbing Supply Fittings

424.1, 424.2, 424.3, 424.4, 424.6, 424.8, Table 605.7, 607.4, 608.2

A112.18.2—2011 / CSA B125.2—2011

Plumbing Waste Fittings

424.1.2

A112.18.3—2002 (Reaffirmed 2008)

Performance Requirements for Backflow Protection Devices and Systems in Plumbing Fixture Fittings

424.2, 424.6

A112.18.6 / CSA B125.6—2009

Flexible Water Connectors

605.6

A112.18.9—2011

Protectors/Insulators for Exposed Waste and Supplies on Accessible Fixtures

404.3

A112.19.1—2013 / CSA B45.2—2013

Enameled Cast Iron and Enameled Steel Plumbing Fixtures

407.1, 410.1, 415.1, 416.1, 418.1

A112.19.2

2013 / CSA B45.1—2013

Ceramic Plumbing Fixtures

401.2, 405.9, 407.1, 408.1, 410.1, 415.1, 416.1, 417.1, 418.1, 419.1, 420.1

A112.19.3— 2008 / CSA B45.4—2008 (R2013)

Stainless Steel Plumbing Fixtures

405.9, 407.1, 415.1, 416.1, 418.1, 420.1

A112.19.5—2011 / CSA B45.15—2011

Flush Valves and Spuds for Water-closets, Urinals, and Tanks

425.4

A112.19.7M—2012 / CSA B45.10—2012

Hydromassage Bathtub Systems

421.1, 421.4

A112.19.12—2006

Wall Mounted and Pedestal Mounted, Adjustable, Elevating, Tilting and Pivoting Lavatory, Sink and Shampoo Bowl Carrier Systems and Drain Systems

416.4, 418.3

A112.19.14—2006 (R2011)

Six-Liter Water Closets Equipped with a Dual Flushing Device

420.1

A112.19.15—2005

Bathtub/Whirlpool Bathtubs with Pressure Sealed Doors

407.4, 421.6

A112.19.19—2006

Vitreous China Nonwater Urinals

419.1

A112.21.3—1985 (R2007)

Hydrants for Utility and Maintenance Use

Table 608.1, 608.13.6

A112.36.2M—1991 (R2008)

Cleanouts

709.1.10.2

ASSE 1016 / ASME A112.1016 / CSA B125.16—2011

Performance Requirements for Individual Thermostatic, Pressure Balancing and Combination Control Valves for Individual Fixture Fittings

424.3, 424.4, 607.4

B1.20.1—1983 (R2006)

Pipe Threads, General Purpose (inch)

605.11.3, 605.13.4, 705.2.3, 705.3.3, 705.6.4, 705.9.1, 705.11.3, 803.3.4.1.3

B16.3—2011

Malleable Iron Threaded Fittings Classes 150 and 300

Table 702.4, Table 1102.7

B16.4—2011

Gray Iron Threaded Fittings Classes 125 and 250

Table 605.5, Table 702.4, Table 1102.7

B16.12—2009

Cast-iron Threaded Drainage Fittings

Table 702.4, Table 1102.7

B16.15—2011

Cast Bronze Threaded Fittings

Table 605.5, Table 702.4

B16.18—2012

Cast Copper Alloy Solder Joint Pressure Fittings

Table 605.5, Table 702.4

B16.22—2001 (R2010)

Wrought Copper and Copper Alloy Solder Joint Pressure Fittings

Table 605.5, Table 702.4

B16.23—2011

Cast Copper Alloy Solder Joint Drainage Fittings (DWV)

Table 702.4

B16.26—2011

Cast Copper Alloy Fittings for Flared Copper Tubes

Table 605.5, Table 702.4

B16.29—2012

Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings (DWV)

Table 702.4

B31.9—2017

Building Services Piping

605.23.2

BPVC—2010

Boiler and Pressure Vessel Code

312.11.1, 501.2

ASPE

American Society of Plumbing Engineers 8614 Catalpa Avenue, Suite 1007 Chicago, IL 60656-1116

Standard reference number

Title

Referenced in code section number

45—2013

Siphonic Roof Drainage Systems

1107.1

ASSE

American Society of Sanitary Engineering 901 Canterbury Road, Suite A Westlake, OH 44145

Standard reference number

Title

Referenced in code section number

1001—08

Performance Requirements for Atmospheric Type Vacuum Breakers

425.2, Table 608.1, 608.13.6, 608.16.4.1

1002—08

Performance Requirements for Antisiphon Fill Valves (Ballcocks) for Gravity Water Closet Flush Tanks

425.3.1, Table 608.1

1003—09

Performance Requirements for Water Pressure Reducing Valves

604.8

1004—08

Performance Requirements for Backflow Prevention Requirements for Commercial Dishwashing Machines

409.1

1008—06

Performance Requirements for Plumbing Aspects of Food Waste Disposer Units

413.1

1010—04

Performance Requirements for Water Hammer Arresters

604.9

1011—04

Performance Requirements for Hose Connection Vacuum Breakers

Table 608.1, 608.13.6

1012—09

Performance Requirements for Backflow Preventers with Intermediate Atmospheric Vent

Table 608.1, 608.13.3, 608.16.2

1013—09

Performance Requirements for Reduced Pressure Principle Backflow Preventers and Reduced Pressure Principle Fire Protection Backflow Preventers

Table 608.1, 608.13.2, 608.16.2

1015—09

Performance Requirements for Double Check Backflow Prevention Assemblies and Double Check Fire Protection Backflow Prevention Assemblies

Table 608.1, 608.13.7

ASSE 1016 / ASME A112.1016 / CSA B125.16—2011

Performance Requirements for Individual Thermostatic, Pressure Balancing and Combination Control Valves for Individual Fixture Fittings

424.3, 424.4, 607.4, 613.1

1017—2010

Performance Requirements for Temperature Actuated Mixing Valves for Hot Water Distribution Systems

501.2.3, 613.1

1018—2010

Performance Requirements for Trap Seal Primer Valves; Potable Water Supplied

1002.4.1.1, 1002.4.1.2

1019—2010

Performance Requirements for Vacuum Breaker Wall Hydrants, Freeze Resistant, Automatic Draining Type

Table 608.1, 608.13.6,

1020—04

Performance Requirements for Pressure Vacuum Breaker Assembly

Table 608.1, 608.13.5

1022—03

Performance Requirements for Backflow Preventer for Beverage Dispensing Equipment

Table 608.1, 608.16.1, 608.16.10

1024—04

Performance Requirements for Dual Check Valve Type Backflow Preventers (for Residential Supply Service or Individual Outlets)

Table 608.1, 608.13.10

1035—08

Performance Requirements for Laboratory Faucet Backflow Preventers

Table 608.1, 608.13.6

1037—90

Performance Requirements for Pressurized Flushing Devices for Plumbing Fixtures

425.2

1047—2009

Performance Requirements for Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies

Table 608.1, 608.13.2

1048—2009

Performance Requirements for Double Check Detector Fire Protection Backflow Prevention Assemblies

Table 608.1, 608.13.7

1052—04

Performance Requirements for Hose Connection Backflow Preventers

Table 608.1, 608.13.6

1055—2009

Performance Requirements for Chemical Dispensing Systems

608.13.9

1056—2010

Performance Requirements for Spill Resistant Vacuum Breaker

Table 608.1, 608.13.5, 608.13.8

1060—2006

Performance Requirements for Outdoor Enclosures for Fluid Conveying Components

608.14.1

1061—2010

Performance Requirements for Removable and Nonremovable Push Fit Fittings

Table 605.5, 605.14.4

1062—2006

Performance Requirements for Temperature Actuated, Flow Reduction Valves to Individual Supply Fittings

424.7

1066—2009

Performance Requirements for Individual Pressure Balancing In-line Valves for Individual Fixture Fittings

604.11

1069—05

Performance Requirements for Automatic Temperature Control Mixing Valves

424.4

1070—04

Performance Requirements for Water-temperature Limiting Devices

408.3, 416.5, 423.3, 424.5, 607.1.2

1079—2005

Performance Requirements for Dielectric Pipe Unions

605.24.1, 605.24.3

5013—2009

Performance Requirements for Testing Reduced Pressure Principle Backflow Prevention Assembly (RPA) and Reduced Pressure Fire Protection Backflow Preventers (RFP)

312.10.2

5015—2009

Performance Requirements for Testing Double Check Valve Backflow Prevention Assemblies (DC) and Double Check Fire Protection Backflow Prevention Assemblies (DCF)

312.10.2

5020—2009

Performance Requirements for Testing Pressure Vacuum Breaker Assemblies (PVBA)

312.10.2

5047—98

Performance Requirements for Testing Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies (RPDA)

312.10.2

5048—2009

Performance Requirements for Testing Double Check Valve Detector Assembly (DCDA)

312.10.2

5052—98

Performance Requirements for Testing Hose Connection Backflow Preventers

312.10.2

5056—98

Performance Requirements for Testing Spill Resistant Vacuum Breaker (SRVB)

312.10.2

ASTM

ASTM International 100 Barr Harbor Drive West Conshohocken, PA 19428-2959

Standard reference number

Title

Referenced in code section number

A 53/ A 53M—12

Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless

Table 702.1, Table 702.3, Table 1102.4

A 74—13A

Specification for Cast-iron Soil Pipe and Fittings

Table 702.1, Table 702.2, Table 702.3, Table 702.4, 708.1.6, Table 1102.4, Table 1102.5, Table 1102.7

A 123—12

Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products

Table 702.3, Table 1102.4

A 153 / A 153M—16a

Specifications for Zinc Coating (Hot Dip) on Iron and Steel Hardware

Table 702.4, Table 1102.7

A 312 / A 312M—13a

Specification for Seamless, Welded, And Heavily Cold Worked Austenitic Stainless Steel Pipes

Table 605.4, Table 605.4.1, Table 605.5, Table 1301.6

A 403 / A 403M—11

Specification for Wrought Austenitic Stainless Steel Piping Fittings

Table 605.5, Table 605.8

A 518 / A 518M—99 (2012)

Standard Specification for Corrosion-Resistant High- Silicon Iron Castings

Table 803.3.1

A 778—01 (2009) e1

Specification for Welded Unannealed Austenitic Stainless Steel Tubular Products

Table 605.4, Table 605.4.1, Table 605.5, Table 1301.6

A 861—04 (2017)

Standard Specification for High-Silicon Iron Pipe and Fittings

Table 803.3.2

A 888—13A

Specification for Hubless Cast-iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Application

Table 702.1, Table 702.2, Table 702.3, Table 702.4, Table 1102.4, Table 1102.5, Table 1102.7

B 32—08

Specification for Solder Metal

605.14.6, 705.6.3, 705.7.3

B 42—10

Specification for Seamless Copper Pipe, Standard Sizes

Table 605.4, Table 605.4.1, Table 702.1, Table 1301.6

B 43—09

Specification for Seamless Red Brass Pipe, Standard Sizes

Table 605.4, Table 605.4.1, Table 702.1, Table 1301.6

B 62—17

Specification for Composition Bronze or Ounce Metal Castings

Table 605.5, Table 702.4, Table 1102.7

B 75—11

Specification for Seamless Copper Tube

Table 605.4, Table 605.4.1, Table 702.1, Table 702.2, Table 702.3, Table 1102.4, Table 1102.7, Table 1301.6

B 88—09

Specification for Seamless Copper Water Tube

Table 605.4, Table 605.4.1, Table 702.1, Table 702.2, Table 702.3, Table 1102.4, Table 1102.7, Table 1301.6, Figure E103.3(2), Figure E103.3(3)

B 152 / B 152M—13

Specification for Copper Sheet, Strip Plate and Rolled Bar

402.3, 417.5.2.4, 425.3.3, 902.2

B 251—10

Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube

Table 605.3, Table 605.4, Table 605.4.1, Table 702.1, Table 702.2, Table 702.3, Table 1102.4, Table 1102.7, Table 1301.6

B 302—12

Specification for Threadless Copper Pipe, Standard Sizes

Table 605.4, Table 605.4.1, Table 702.1, Table 1301.6

B 447—12a

Specification for Welded Copper Tube

Table 605.4, Table 605.4.1, Table 1301.6

B 687— (2011)

Specification for Brass, Copper and Chromium-plated Pipe Nipples

Table 605.8

B 813—10

Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube

605.14.6, 705.6.3, 705.7.3

B 828—02 (2010)

Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings

605.14.6, 705.6.3, 705.7.3

C 4—04 (2009)

Specification for Clay Drain Tile and Perforated Clay Drain Tile

Table 702.3, Table 1102.4, Table 1102.5

C 14—11

Specification for Nonreinforced Concrete Sewer, Storm Drain and Culvert Pipe

Table 702.3, Table 1102.4

C 76—13a

Specification for Reinforced Concrete Culvert, Storm Drain and Sewer Pipe

Table 702.3, Table 1102.4

C 425—04 (2009)

Specification for Compression Joints for Vitrified Clay Pipe and Fittings

Table 702.4, 705.12, 705.16, Table 1102.7

C 443—12

Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets

705.5, 705.16

C 564—12

Specification for Rubber Gaskets for Cast-iron Soil Pipe and Fittings

705.4.2, 705.4.3, 705.16

C 654—15

Standard Specification for Porous Concrete Pipe

Table 1102.5

C 700—13

Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength, and Perforated

Table 702.3, Table 702.4, Table 1102.4, Table 1102.5

C 1053—00 (2010)

Specification for Borosilicate Glass Pipe and Fittings for Drain, Waste, and Vent (DWV) Applications

Table 803.3.1, Table 803.3.2

C 1173—10e1

Specification for Flexible Transition Couplings for Underground Piping System

705.2.1, 705.5, 705.11.1, 705.12, 705.13.2, 705.16,

C 1277—12

Specification for Shielded Coupling Joining Hubless Cast-iron Soil Pipe and Fittings

705.4.3

C 1440—08

Specification for Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Waste, and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems

705.16

C 1460—08

Specification for Shielded Transition Couplings for Use with Dissimilar DWV Pipe and Fittings Above Ground

705.16

C 1461—08

Specification for Mechanical Couplings Using Thermoplastic Elastomeric (TPE) Gaskets for Joining Drain, Waste and Vent (DWV) Sewer, Sanitary and Storm Plumbing Systems for Above and Below Ground Use

705.16

C 1540—11

Specification for Heavy Duty Shielded Couplings Joining Hubless Cast-iron Soil Pipe and Fittings

705.4.3

C 1563—13

Standard Test Method for Gaskets for Use in Connection with Hub and Spigot Cast Iron Soil Pipe and Fittings for Sanitary Drain, Waste, Vent and Storm Piping Applications

705.4.2

D 1586—11

Standard Test Method for Standard Penetration Test (SPT) and Split-barrel Sampling of Soils

1114.2.1

D 1587—15

Standard Practice for Thin-walled Tube Sampling of Soils for Geotechnical Purposes

1114.2.1

D 2235—04 (2011)

Specification for Solvent Cement for Acrylonitrile- Butadiene-Styrene (ABS) Plastic Pipe and Fittings

705.2.2

D 2464—15

Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80

Table 1102.7

D 2466—17

Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40

Table 1102.7

D 2467—15

Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80

Table 1102.7

D 2564—12

Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems

705.11.2

D 2657—07

Practice for Heat Fusion-joining of Polyolefin Pipe and Fitting Waste, and Vent Pipe and Fittings

705.13.1, Table 1102.7

D 2661—11

Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe and Fittings

Table 702.1, Table 702.4, 705.2.2, Table 1102.7

D 2665—12

Specification for Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings

Table 702.1, Table 702.2, Table 702.3, Table 702.4, Table 1102.4, Table 1102.7, Table 1403.2.1

D 2729—11

Specification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings

Table 1102.5, Table 1403.2

D 2751—05

Specification for Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe and Fittings

Table 702.4, Table 1102.7

D 2846—09be1

Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot and Cold Water Distribution Systems

Table 1301.6

D 2855—96 (2010)

Standard Practice for Making Solvent-cemented Joints with Poly (Vinyl Chloride) (PVC) Pipe and Fittings

705.11.2

D 2949—10

Specification for 3.25-in Outside Diameter Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings

Table 702.1, Table 702.4, Table 1403.2.1

D 3034—08

Specification for Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings

Table 702.3, Table 702.4, Table 1102.4, Table 1102.5, Table 1102.7, Table 1403.2.1

D 3212—07

Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals

705.2.1, 705.11.1, 705.13.2

D 3311—11

Specification for Drain, Waste and Vent (DWV) Plastic Fittings Patterns

Table 1102.7

D 3350—14

Specification for High Density Polyethylene Pipe (HPDE)

Table 1102.4, Table 1102.7

D 4068—09

Specification for Chlorinated Polyethlene (CPE) Sheeting for Concealed Water-containment Membrane

417.5.2.2

D 4551—12

Specification for Poly (Vinyl Chloride) (PVC) Plastic Flexible Concealed Water-containment Membrane

417.5.2.1

F 405—05

Specification for Corrugated Polyethylene (PE) Pipe and Fittings

Table 1102.5, Table 1403.2, Table 1403.2.1

F 409—12

Specification for Thermoplastic Accessible and Replaceable Plastic Tube and Tubular Fittings

424.1.2

F 437—15

Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80

Table 702.3, Table 702.4, Table 1102.4, Table 1102.7

F 438—17

Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40

Table 702.3, Table 702.4, Table 1102.4, Table 1102.7

F 439—13

Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80

Table 702.3, Table 702.4, Table 1102.4, Table 1102.7

F 477—10

Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe

705.16

F 628—08

Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe with a Cellular Core

Table 702.1, Table 702.4, 705.2.2, Table 1102.7

F 656—10

Specification for Primers for Use in Solvent Cement Joints of Poly (Vinyl Chloride) (PVC) Plastic Pipe and Fittings

705.11.2

F 891—10

Specification for Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe with a Cellular Core

Table 702.1 Table 702.2, Table 702.3, Table 1102.4, Table 1102.5

F 1412—09

Specification for Polyolefin Pipe and Fittings for Corrosive Waste Drainage

Table 702.2, Table 803.3.1, Table 803.3.2, 803.3.4.4.1, 803.3.4.5.1, Table 1102.7

F 1488—09e1

Specification for Coextruded Composite Pipe

Table 702.1, Table 702.2, Table 1403.2

F 1673—10

Polyvinylidene Fluoride (PVDF) Corrosive Waste Drainage Systems

Table 803.3.1, Table 803.3.2, 803.3.4.6.1, Table 1102.7

F 1866—07

Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and DWV Fabricated Fittings

Table 702.4, Table 1102.7, Table 1403.2.1

F 2306 / F 2306M—13

12'' to 60'' Annular Corrugated Profile-wall Polyethylene (PE) Pipe and Fittings for Gravity Flow Storm Sewer and Subsurface Drainage Applications

Table 702.4, Table 1102.7

F 2389—10

Specification for Pressure-rated Polypropylene (PP) Piping Systems

Table 1301.6, Table 1403.2, Table 1403.2.1

F 2618—15

Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Pipe and Fittings for Chemical Waste Drainage Systems

Table 803.3.1, Table 803.3.2, 803.3.4.1.2

F 2764—17e1

Standard Specification for 6 to 60 in. Polypropylene (PP) Corrugated Double and Triple Wall Pipe

Table 1102.5

F 3219—17

Standard Specification for 3 to 30 in. (75 To 750 mm) Polypropylene (PP) Corrugated Single Wall Pipe and Fittings

Table 1102.5

AWS

American Welding Society 8669 NW 36 Street, #130 Doral, FL 33166

Standard reference number

Title

Referenced in code section number

A5.8M / A5.8—2011

Specifications for Filler Metals for Brazing and Braze Welding

605.11.1, 605.13.1, 605.14.1, 705.3.1, 705.6.1, 705.7.1,

AWWA

American Water Works Association 6666 West Quincy Avenue Denver, CO 80235

Standard reference number

Title

Referenced in code section number

C110 / A21.10—12

Ductile-iron and Gray-iron Fittings

Table 605.5, Table 702.4, Table 1102.7

C111 / A21.11—12

Rubber-gasket Joints for Ductile-iron Pressure Pipe and Fittings

605.12

C115 / A21.15—11

Flanged Ductile-iron Pipe with Ductile-iron or Gray-iron Threaded Flanges

Table 605.4, Table 605.4.1

C151 / A21.51—02

Standard for Ductile-iron Pipe, Centrifugally Cast for Water

Table 605.4, Table 605.4.1, Table 702.1, Table 702.2. Table 702.3, Table 1102.4

C153—00 / A21.53—11

Ductile-iron Compact Fittings for Water Service

Table 605.5

C500—09

Standard for Metal-Seated Gate Valves for Water Supply Service

Table 605.7

C504—10

Standard for Rubber-Seated Butterfly Valves

Table 605.7

C507—11

Standard for Ball Valves, 6 In. Through 60 In

Table 605.7

C510—07

Double Check Valve Backflow Prevention Assembly

Table 608.1, 608.13.7

C511—07

Reduced-pressure Principle Backflow Prevention Assembly

Table 608.1, 608.13.2, 608.16.2

C651—05

Disinfecting Water Mains

610.1

C652—11

Disinfection of Water-storage Facilities

610.1

D100—2005

Standard for Welded Carbon Steel Tanks for Water Storage

1302.7.2, 1303.10.2

D115—2006

Standard for Tendon Prestressed-Concrete Water Tanks

1302.7.2, 1303.10.2

D120—2009

Standard for Thermosetting Fiberglass Reinforced Plastic Tanks

1302.7.2, 1303.10.2

CISPI

Cast Iron Soil Pipe Institute 5959 Shallowford Road, Suite 419 Chattanooga, TN 37421

Standard reference number

Title

Referenced in code section number

301—04a

Specification for Hubless Cast-iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications

Table 702.1, Table 702.2, Table 702.3, Table 702.4, Table 1102.4, Table 1102.5, Table 1102.7

310—11

Specification for Coupling for Use in Connection with Hubless Cast-iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications

308.5.1, 308.6.1, 705.4.3

CSA

CSA Group 8501 East Pleasant Valley Cleveland, OH 44131-5516

Standard reference number

Title

Referenced in code section number

A257.1M—2009

Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings

Table 702.3, Table 1102.4

A257.2M—2009

Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings

Table 702.3, Table 1102.4

A257.3M—2009

Joints for Circular Concrete Sewer and Culvert Pipe, Manhole Sections and Fittings Using Rubber Gaskets

705.5, 705.16

ASME A112.3.4—2013 / CSA B45.9—2013

Macerating Systems and Related Components

712.4.1

ASME A112.18.1—2012 / CSA B125.1—2012

Plumbing Supply Fittings

424.1, 424.2, 424.3, 424.4, 424.6, 424.8, Table 605.7, 607.4, 608.2

ASME A112.18.2—2011 / CSA B125.2—2011

Plumbing Waste Fittings

424.1.2

ASME A112.19.1—2013 / CSA B45.2—2013

Enameled Cast-iron and Enameled Steel Plumbing Fixtures

407.1, 410.1, 415.1, 416.1, 418.1

ASME A112.19.2—2013 / CSA B45.1—2013

Ceramic Plumbing Fixtures

401.2, 405.9, 407.1, 408.1, 410.1, 415.1, 416.1, 417.1, 418.1, 419.1, 420.1

ASME A112.19.3—2008 / CSA B45.4—08 (R2013)

Stainless-steel Plumbing Fixtures

405.9, 407.1, 415.1, 416.1, 418.1, 420.1

ASME A112.19.5—2011 / CSA B45.15—2011

Flush Valves and Spuds for Water-closets, Urinals and Tanks

425.4

ASME A112.19.7—2012 / CSA B45.10—2012

Hydromassage Bathtub Systems

421.1, 421.4

ASSE 1016 / ASME A112.1016 / CSA B125.16—2011

Performance Requirements for Individual Thermostatic, Pressure Balancing and Combination Control Valves for Individual Fixture Fittings

424.3, 424.4, 607.4

CSA B45.5—11 / IAPMO Z124—2011

Plastic Plumbing Fixtures

407.1, 415.1, 416.1, 416.2, 417.1, 418.1, 419.1, 420.1

B64.1.1—11

Vacuum Breakers, Atmospheric Type (AVB)

425.2, Table 608.1, 608.13.6, 608.16.4.1

B64.1.2—11

Pressure Vacuum Breakers, (PVB)

Table 608.1, 608.13.5

B64.1.3—11

Spill Resistant Pressure Vacuum Breaks (SRPVB)

608.13.8

B64.2—11

Vacuum Breakers, Hose Connection Type (HCVB)

Table 608.1, 608.13.6

B64.2.1—11

Vacuum Breakers, Hose Connection (HCVB) with Manual Draining Feature

Table 608.1, 608.13.6

B64.2.1.1—11

Hose Connection Dual Check Vacuum Breakers, (HCDVB)

Table 608.1, 608.13.6

B64.2.2—11

Vacuum Breakers, Hose Connection Type (HCVB) with Automatic Draining Feature

Table 608.1, 608.13.6

B64.3—11

Backflow Preventers, Dual Check Valve Type with Atmospheric Port (DCAP)

Table 608.1, 608.13.3, 608.16.2

B64.4—11

Backflow Preventers, Reduced Pressure Principle Type (RP)

Table 608.1, 608.13.2

B64.4.1—11

Reduced Pressure Principle for Fire Sprinklers (RPF)

Table 608.1, 608.13.2

B64.5—11

Double Check Backflow Preventers (DCVA)

Table 608.1, 608.13.7

B64.5.1—11

Double Check Valve Backflow Preventer for Fire Systems (DCVAF)

Table 608.1 608.13.7

B64.6—11

Dual Check Backflow Preventers Valve (DuC)

Table 608.1, 608.13.10

B64.7—11

Laboratory Faucet Vacuum Breakers (LFVB)

Table 608.1, 608.13.6

B64.10—11

Manual for the Selection and Installation of Backflow Prevention Devices

312.10.2

B64.10.1—11

Maintenance and Field Testing of Backflow Preventers

312.10.2

B79—08 (R2013)

Commercial and Residential Drains, and Cleanouts

412.1

B125.3—2012

Plumbing Fittings

408.3, 423.3, 424.4, 424.5, 425.2, 425.3.1, Table 605.7

B137.2—02

PVC Injection-Moulded Gasketed Fittings for Pressure Applications

Table 1102.7

B137.3—13

Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications

705.11.2

B181.1—11

Acrylonitrile-butadiene-styrene ABS Drain, Waste and Vent Pipe and Pipe Fittings

Table 702.1, Table 702.4, 705.2.2, 715.2, Table 1102.7

B181.2—11

Polyvinylchloride PVC and chlorinated polyvinylchloride (CPVC) Drain, Waste, and Vent Pipe and Pipe Fittings

Table 702.1 Table 702.2, Table 702.3, 705.11.2, 715.2, Table 1102.4

B181.3—11

Polyolefin and Polyvinylidene Fluoride (PVDF) Laboratory Drainage Systems

Table 803.3.1, Table 803.3.2, 803.3.4.4.1, Table 1102.7

B182.1—11

Plastic Drain and Sewer Pipe and Pipe Fittings

705.11.2, Table 1102.5

B182.2—11

PSM Type Polyvinylchloride PVC Sewer Pipe and Fittings

Table 702.3, Table 1102.4, Table 1102.5

B182.4—11

Profile Polyvinylchloride PVC Sewer Pipe and Fittings

Table 702.3, Table 1102.4, Table 1102.5

B182.6—11

Profile Polyethylene (PE) Sewer Pipe and Fittings for Leak- proof Sewer Applications

Table 1102.5

B182.8—11

Profile Polyethylene (PE) Storm Sewer and Drainage Pipe and Fittings

Table 1102.5

B356—10

Water Pressure Reducing Valves for Domestic Water Systems

604.8

B483.1—14

Drinking Water Treatment Units

611.1, 611.2

B602—10

Mechanical Couplings for Drain, Waste and Vent Pipe and Sewer Pipe

705.2.1, 705.4.3, 705.5, 705.11.1, 705.12, 705.13.2, 705.16

IAPMO

IAPMO Group 4755 E. Philadelphia Ontario, CA 91761

Standard reference number

Title

Referenced in code section number

PS 117—08

Copper and Copper Allow Tubing System Incorporating Press-type or Nail-type Connections

605.14.4

CSA B45.5—11 / IAPMO Z124—2011

Plastic Plumbing Fixtures

407.1, 415.1, 416.1, 416.2, 417.1, 418.1, 419.1, 420.1

ICC

International Code Council, Inc. 500 New Jersey Ave, NW 6th Floor Washington, DC 20001

Standard reference number

Title

Referenced in code section number

A117.1—2009

Accessible and Usable Buildings and Facilities

404.2, 410.1

ISEA

International Safety Equipment Association 1901 N. Moore Street, Suite 808 Arlington, VA 22209

Standard reference number

Title

Referenced in code section number

ANSI / ISEA Z358.1—2009

Emergency Eyewash and Shower Equipment

411.1

MSS

Manufacturers Standardization Society of the Valve and Fittings Industry, Inc. 127 Park St. NE Vienna, VA 22180-4602

Standard reference number

Title

Referenced in code section number

SP-67—2011

Butterfly Valves

Table 605.7

SP-70—2011

Gray Iron Gate Valves, Flanged and Threaded Ends

Table 605.7

SP-71—2011

Gray Iron Swing Check Valves, Flanged and Threaded Ends

Table 605.7

SP-72—2010

Ball Valves with Flanged or Butt-Welding Ends for General Service

Table 605.7

SP-78—2011

Cast Iron Plug Valves, Flanged and Threaded Ends

Table 605.7

SP-80—2008

Bronze Gate, Globe, Angle and Check Valves

Table 605.7

SP-110—2010

Ball Valves, Threaded, Socket Welded, Solder Joint, Grooved and Flared Ends

Table 605.7

NFPA

National Fire Protection Association 1 Batterymarch Park Quincy, MA 02169-7471

Standard reference number

Title

Referenced in code section number

51—13

Design and Installation of Oxygen-fuel Gas Systems for Welding, Cutting and Allied Processes

1201.1, 1203.1

55—13

Compressed Gases and Cryogenic Fluids Code

1201.1, 1203.1

99—15

Health Care Facilities Code

1201.1, 1202.1

NSF

NSF International 789 Dixboro Road Ann Arbor, MI 48105

Standard reference number

Title

Referenced in code section number

3—2010

Commercial Warewashing Equipment

409.1

14—2011

Plastic Piping System Components and Related Materials

303.3, 611.3

18—2012

Manual Food and Beverage Dispensing Equipment

426.1

42—2011

Drinking Water Treatment Units-Aesthetic Effects

611.1, 611.3

44—2012

Residential Cation Exchange Water Softeners

611.1, 611.3

53—2011a

Drinking Water Treatment Units—Health Effects

611.1, 611.3

58—2012

Reverse Osmosis Drinking Water Treatment Systems

611.2, 611.3

61—2012

Drinking Water System Components—Health Effects

410.1, 424.1, 605.4, 605.4.1, 605.5, 605.7, 606.5.4.2, 611.3

62—2012

Drinking Water Distillation Systems

611.1

372—2010

Drinking Water Systems Components—Lead Content

605.2

PDI

Plumbing and Drainage Institute 800 Turnpike Street, Suite 300 North Andover, MA 01845

Standard reference number

Title

Referenced in code section number

G101 (2012)

Testing and Rating Procedure for Grease Interceptors with Appendix of Sizing and Installation Data

1003.3.4

UL

UL LLC 333 Pfingsten Road Northbrook, IL 60062-2096

Standard reference number

Title

Referenced in code section number

58—1996

Steel Underground Tanks for Flammable and Combustible Liquids—with revisions through July 27, 1998

1302.7.2, 1303.10.2

142—2006

Steel Aboveground Tanks for Flammable and Combustible Liquids—with revisions through February 12, 2010

1302.7.2, 1303.10.2

174—2004

Household Electric Storage Tank Water Heaters—with revisions through September 2012

502.1

430—2009

Waste Disposers—with revisions through March 23, 2011

413.1

732—1995

Oil-fired Storage Tank Water Heaters—with revisions through April 2010

502.1

921—2004

Integral gas fired heating commercial dishwashers

409.1

1316—1994

Glass-Fiber Reinforced Plastic Underground Storage Tanks for Petroleum Products, Alcohols and Alcohol Gasoline Mixtures—with revisions through May 12, 2006

1302.7.2, 1303.10.2

1453—2004

Electric Booster and Commercial Storage Tank Water Heaters—with revisions through July 2011

502.1

1746—2007

External Corrosion Protection Systems for Steel Underground Storage Tanks

1302.7.2, 1303.10.2

1795—2009

Hydromassage Bathtubs including revisions through August 23, 2011

421.1

WaterSense

WaterSense U.S. Environmental Protection Agency Office of Wastewater Management (4204M) 1200 Pennsylvania Avenue, N.W. Washington, D.C. 20460

Standard reference number

Title

Referenced in code section number

v.1.0—October 1, 2007

High-efficiency Lavatory Faucet Specifications

604.4.1

v.1.0—October 8, 2009

WaterSense Specification for Flushing Urinals

604.4.1

v.1.0—December 17, 2015

WaterSense Specification for Flushometer-Valve Water Closets

604.4.1

v.1.1—July 26, 2018

WaterSense Specification for Showerheads

604.4.1

v.1.2—June 2, 2014

WaterSense Specification for Tank-Type Toilets

604.4.1