309.1 General.

Plumbing systems and equipment in structures erected in flood hazard areas shall be constructed in accordance with the requirements of this section and Appendix G of the New York City Building Code.

309.2 Flood hazard.

For structures located in flood hazard areas, the following systems and equipment shall be located and installed as required by

Appendix G

of the

New York City Building Code

:

1. Water service pipes.

2. Pump seals in individual water supply systems where the pump is located below the design flood elevation.

3. Covers on potable water wells shall be sealed, except where the top of the casing well or pipe sleeve is elevated to not less than 1 foot (305 mm) above the design flood elevation.

4. Sanitary drainage piping.

5. Storm drainage piping.

6. Manhole covers shall be sealed, except where elevated to or above the design flood elevation.

7. Other plumbing fixtures, faucets, fixture fittings, piping systems and equipment.

8. Water heaters.

9. Vents and vent systems.

Exception:

In accordance with

Appendix G

of the

New York City Building Code

, the above systems are permitted to be located below the design flood elevation provided that the systems are designed and installed to prevent water from entering or accumulating within their components and the systems are constructed to resist hydrostatic and hydrodynamic loads and stresses, including the effects of buoyancy, during the occurrence of flooding to the design flood elevation.

309.3 Coastal high-hazard areas and coastal A zones.

Structures located in coastal high-hazard areas and coastal A zones shall meet the requirements of Section 309.2. The plumbing systems, pipes and fixtures shall not be mounted on or penetrate through walls intended to break away under flood loads.