12VAC5-421-2790: Indoor areas; surface characteristics
Where this section sits in the code
- Title 12. Health
- Agency 5. Department of Health
- Chapter 421. Food Regulations
- Part VI. Physical Facilities
- Article 1. Materials for Construction and Repair
A. Except as specified in subsection B of this section, materials for indoor floor, wall, and ceiling surfaces under conditions of normal use shall be:
1. Smooth, durable, and easily cleanable for areas where food establishment operations are conducted;
2. Closely woven and easily cleanable carpet for carpeted areas; and
3. Nonabsorbent for areas subject to moisture such as food preparation areas, walk-in refrigerators, warewashing areas, toilet rooms, mobile food establishment servicing areas, and areas subject to flushing or spray cleaning methods.
B. In a temporary food establishment:
1. A floor may be concrete, if graded to drain, machine-laid asphalt, or dirt or gravel if it is covered with mats, removable platforms, duckboards, or other approved materials that are effectively treated to control dust and mud; and
2. Walls and ceilings may be constructed of a material that protects the interior from the weather and windblown dust and debris.