12VAC5-481-2850: Personnel monitoring
Where this section sits in the code
- Title 12. Health
- Agency 5. Department of Health
- Chapter 481. Virginia Radiation Protection Regulations
- Part XII. Licensing and Radiation Safety Requirements for Irradiators
- Article 4. Operation of Irradiators
A. Irradiator operators shall wear a personnel dosimeter while operating a panoramic irradiator or while in the area around the pool of an underwater irradiator. The personnel dosimeter must be capable of detecting high energy photons in the normal and accident dose ranges (see 12VAC5-481-750). Each personnel dosimeter shall be assigned to and worn by only one individual. Film badges shall be processed at least monthly, and other personnel dosimeters that require replacement shall be evaluated at least quarterly or promptly after replacement, whichever is more frequent.
B. Other individuals who enter the radiation room of a panoramic irradiator shall wear a dosimeter, which may be a pocket dosimeter. For groups of visitors, only two people who enter the radiation room are required to wear dosimeters. If pocket dosimeters are used to meet the requirements of this subsection, a check of their response to radiation shall be done at least annually. Acceptable dosimeters shall read within plus or minus 30% of the true radiation dose.