12VAC5-481-2880: Inspection and maintenance

Read at publisher ↗
Where this section sits in the code
  1. Title 12. Health
  2. Agency 5. Department of Health
  3. Chapter 481. Virginia Radiation Protection Regulations
  4. Part XII. Licensing and Radiation Safety Requirements for Irradiators
  5. Article 4. Operation of Irradiators

A. Licensees shall perform inspection and maintenance checks that include, as a minimum, each of the following at the frequency specified in the license or license application:

1. Operability of each aspect of the access control system required by 12VAC5-481-2730;

2. Functioning of the source position indicator required by 12VAC5-481-2770 B;

3. Operability of the radiation monitor for radioactive contamination in pool water required by 12VAC5-481-2870 B using a radiation check source, if applicable;

4. Operability of the over-pool radiation monitor at underwater irradiators as required by 12VAC5-481-2760 B;

5. Operability of the product exit monitor required by 12VAC5-481-2760 A;

6. Operability of the emergency source return control required by 12VAC5-481-2770 C;

7. Leak-tightness of systems through which pool water circulates (visual inspection);

8. Operability of the heat and smoke detectors and extinguisher system required by 12VAC5-481-2750 (but without turning extinguishers on);

9. Operability of the means of pool water replenishment required by 12VAC5-481-2780 C;

10. Operability of the indicators of high and low pool water levels required by 12VAC5-481-2780 D;

11. Operability of the intrusion alarm required by 12VAC5-481-2730 I, if applicable;

12. Functioning and wear of the system, mechanisms, and cables used to raise and lower sources;

13. Condition of the barrier to prevent products from hitting the sources or source mechanism as required by 12VAC5-481-2790;

14. Amount of water added to the pool to determine if the pool is leaking;

15. Electrical wiring on required safety systems for radiation damage; and

16. Pool water conductivity measurements and analysis as required by 12VAC5-481-2890 B.

B. Malfunctions and defects found during inspection and maintenance checks shall be repaired without undue delay.