12VAC5-481-3200: Radiation survey instruments
Where this section sits in the code
- Title 12. Health
- Agency 5. Department of Health
- Chapter 481. Virginia Radiation Protection Regulations
- Part XIV. Radiation Safety Requirements for Wireline Service Operations and Subsurface Tracer Studies
- Article 3. Equipment Control
A. The licensee or registrant shall maintain sufficient calibrated and operable radiation survey instruments at each field station to make physical radiation surveys as required by this part and by Part IV (12VAC5-481-600 et seq.). Instrumentation shall be capable of measuring 0.001 mSv (0.1 mrem) per hour through at least 0.5 mSv (50 mrem) per hour.
B. Each radiation survey instrument shall be calibrated:
1. At intervals not to exceed six months and after each instrument servicing;
2. For linear scale instruments, at two points located approximately 25% and 75% of full-scale on each scale; for logarithmic scale instruments, at midrange of each decade, and at two points of at least one decade; and for digital instruments, at appropriate points; and
3. So that accuracy within 20% of the true radiation level can be demonstrated on each scale.
C. Calibration records shall be maintained for a period of three years.