When installing point-anchor rock bolts:

1. A torque test shall be conducted on at least every fourth installed bolt;

2. Torque testing shall be conducted immediately after bolt installation;

3. If the recommended torque has not been achieved, the equipment used to install the bolt shall be adjusted and the next bolt installed shall then be tested; and

4. If the recommended torque has not been achieved on the majority of bolts installed in a working place through equipment adjustment, supplemental support equivalent to longer roof bolts with adequate anchorage, steel or wood sets, or cribs shall be installed.