4VAC25-40-5590: Fan installation doors

Read at publisher ↗
Where this section sits in the code
  1. Title 4. Conservation And Natural Resources
  2. Agency 25. Department of Energy
  3. Chapter 40. Safety and Health Regulations for Mineral Mining
  4. Part XV. Safety and Health Regulations—Underground Only
  5. Article 11. Gassy Mines

In mines ventilated by a combination of multiple blowing or multiple exhausting fans, each main fan installation shall be equipped with noncombustible doors designed and positioned so that, in the event of failure of a main fan, these doors will automatically close to prevent air reversal through the fan. The doors shall be located so that they are not in direct line with forces which would come out of the mine, should an explosion occur.