4VAC50-20-501: Exemption from general permit requirements for certain low hazard potential impounding structures
Where this section sits in the code
- Title 4. Conservation And Natural Resources
- Agency 50. Virginia Soil And Water Conservation Board
- Chapter 20. Impounding Structure Regulations
- Part VII. General Permit for Low Hazard Potential Impounding Structure Requirements
A. In accordance with § 10.1-605.3 of the Code of Virginia, should the failure of a low hazard potential impounding structure cause no expected loss of human life and no economic damage to any property except property owned by the impounding structure owner, the owner may choose to meet the following requirements instead of the requirements specified in the general permit for low hazard impounding structures:
1. A licensed professional engineer certifies that the impounding structure is a low hazard potential impounding structure that will cause no expected loss of human life and no economic damage to any property except property owned by the impounding structure owner;
2. The owner of an impounding structure shall notify the local emergency management coordinator in the event of a failure or emergency condition at the impounding structure; however, no emergency preparedness plan prepared pursuant to 4VAC50-20-177 shall be required; and
3. The owner of an impounding structure shall perform inspections of the impounding structure annually in accordance with the requirements of 4VAC50-20-105.
B. No specific spillway design flood is required for a dam that meets the criteria established in subsection A of this section, although the recommended minimum spillway design flood is a 50-year flood.
C. Any owner of an impounding structure electing to utilize the requirements of subsection A of this section shall otherwise comply with all other requirements of this chapter applicable to low hazard impounding structures.
D. The owner shall notify the department immediately of any change in circumstances that would cause the impounding structure to no longer qualify to utilize the provisions of this section.
E. No certificate or permit fee established in this chapter shall be applicable to the impounding structure.
Collected 2026-09-14T04:46:25Z. Source file · JSON