6VAC15-81-1040: Jail equipment
Where this section sits in the code
- Title 6. Criminal Justice And Corrections
- Agency 15. State Board of Local and Regional Jails
- Chapter 81. Standards for Planning, Design, Construction, and Reimbursement of Local Correctional Facilities
- Part V. Secure Local Correctional Facilities Design and Construction
- Article 6. Miscellaneous Construction Features
A. All jail security equipment, fixtures, hardware, etc. shall be of a design to meet the security level consistent with the intended use of the space.
B. Bunks installed in maximum and medium security cells shall be bolted through the wall, welded to imbeds, or bolted or welded to inserts cast into the wall or floor.
C. Fixed tables and seats shall be through-bolted through the wall, welded to imbeds, or bolted or welded to inserts cast into the wall or floor.
D. Door closers within the secure perimeter shall be the concealed arm type.
E. All equipment and systems shall be installed in accordance with manufacturer instructions unless otherwise required by this chapter or approved by the reviewing authority to be installed differently.
F. Exposed surfaces of all metal tables, bunks, seats, cabinets, grab rails, stringers, hand and guard rails, food passes, windows, doors, frames, shelves, and similar items shall have smooth edges to reduce risk of cutting or other injury.