9VAC25-280-40: Ground water standards applicable statewide
Where this section sits in the code
- Title 9. Environment
- Agency 25. State Water Control Board
- Chapter 280. Ground Water Standards
CONSTITUENT
CONCENTRATION
Sodium
270 mg/l
Foaming Agents as methylene blue active substances
0.05 mg/l
Petroleum hydrocarbons
1 mg/l
Arsenic
0.05 mg/l
Barium
1.0 mg/l
Cadmium
0.0004 mg/l
Chromium
0.05 mg/l
Copper
1.0 mg/l
Cyanide
0.005 mg/l
Lead
0.05 mg/l
Mercury
0.00005 mg/l
Phenols
0.001 mg/l
Selenium
0.01 mg/l
Silver
None
Zinc
0.05 mg/l
Chlorinated Hydrocarbon Insecticides
Aldrin/Dieldrin
0.003 μg/l
Chlordane
0.01 μg/l
DDT
0.001 μg/l
Endrin
0.004 μg/l
Heptachlor
0.001 μg/l
Heptachlor Epoxide
0.001 μg/l
Kepone
None
Lindane
0.01 μg/l
Methoxychlor
0.03 μg/l
Mirex
None
Toxaphene
None
Chlorophenoxy Herbicides
2,4‑D
0.1 mg/l
Silvex
0.01 mg/l
Radioactivity
Total Radium (Ra‑226 & Ra‑228)
5 pCi/1
Radium 226
3 pCi/1
Gross Beta Activity*
50 pCi/1
Gross Alpha Activity (excluding Radon & Uranium)
15 pCi/1
Tritium
20,000 pCi/l
Strontium‑90
8 pCi/l
Manmade Radioactivity ‑ Total Dose Equiv.**
4 mrem/yr
pCi/l = picoCurie per liter
mrem/yr = millirems per year
*The gross beta value shall be used as a screening value only. If exceeded, the water must be analyzed to determine the presence and quantity of radionuclides to determine compliance with the tritium, strontium, and manmade radioactivity standards.
**Combination of all sources should not exceed total dose equivalent of 4 mrem/year.
Collected 2026-09-14T04:49:15Z. Source file · JSON