9VAC5-40-2710: Standard for particulate matter

Read at publisher ↗
Where this section sits in the code
  1. Title 9. Environment
  2. Agency 5. State Air Pollution Control Board
  3. Chapter 40. Existing Stationary Sources
  4. Part II. Emission Standards
  5. Article 20. Emission Standards for Feed Manufacturing Operations (Rule 4-20)

A. No owner or other person shall cause, or permit to be discharged into the atmosphere from any feed manufacturing operation any particulate emissions in excess of the limits in Table 4-20.

TABLE 4-20

Process Weight

Maximum Allowable Emission Rate

Lb/Hr

Tons/Hr

Lb/Hr

100 or less

0.05 or less

0.551

200

0.10

0.877

400

0.20

1.40

600

0.30

1.83

800

0.40

2.22

1000

0.50

2.58

1500

0.75

3.38

2000

1.00

4.10

2500

1.25

4.76

3000

1.50

5.38

3500

1.75

5.96

4000

2.00

6.52

5000

2.50

7.58

6000

3.00

8.56

7000

3.50

9.49

8000

4.00

10.4

9000

4.50

11.2

10000

5.00

12.0

12000

6.00

13.6

16000

8.00

16.5

18000

9.00

17.9

20000

10.00

19.2

30000

15.00

25.2

40000

20.00

30.5

50000

25.00

35.4

60000

30.00

40.0

70000

35.00

41.3

80000

40.00

42.5

90000

45.00

43.6

100000

50.00

44.6

120000

60.00

46.3

140000

70.00

47.8

160000

80.00

49.1

200000

100.00

51.3

1000000

500.00

69.0

2000000

1000.00

77.6

6000000

3000.00

92.7

B. Except as provided in subsections C and D of this section, interpretation of the emission standard in subsection A of this section shall be in accordance with 9VAC5-40-22.

C. The process weight rate entry to be used in Table 4-20 for feed manufacturing process units shall be considered as the production rate.

D. The process weight rate entry to be used in Table 4-20 for feed manufacturing operations involving physically connected dissimilar process operations shall be the sum of the process weight rates of each of the dissimilar process operations. The materials handling equipment shall not be considered as a part of the process operation for determination of process weight rate.

E. The provisions of this section shall not apply to affected facilities identified in subsection A of this section and located in AQCR 7; however, the provisions of 9VAC5-40-270 shall apply to the facilities.

Collected 2026-09-14T04:48:08Z. Source file · JSON

Browse this collection