(a) Initial drug testing. (1) HHS-certified laboratories shall apply the following cutoff levels for initial testing of specimens to determine whether they are negative or positive for the indicated drugs and drug metabolites, except as specified in paragraph (a)(2) of this section or the licensee or other entity has established more stringent cutoff levels:

Table 1 to Paragraph (a)(1)—Urine, Initial Test Cutoff Levels for Drugs and Drug Metabolites

Drugs or drug metabolites Cutoff level [nanograms (ng)/mL]

Marijuana metabolites 50

Cocaine metabolites 150

Opioids:

Codeine/Morphine1 2,000

Hydrocodone/Hydromorphone 300

Oxycodone/Oxymorphone 100

6-acetylmorphine (6-AM) 10

Phencyclidine (PCP) 25

Amphetamines: 2

AMP/MAMP 3 500

MDMA 4/MDA 5 500

1 Morphine is the target analyte for codeine/morphine testing.

2 Either a single initial test kit or multiple initial test kits may be used provided the single test kit detects each target analyte independently at the specified cutoff.

3 Methamphetamine (MAMP) is the target analyte for amphetamine (AMP)/MAMP testing.

4 Methylenedioxymethamphetamine.

5 Methylenedioxyamphetamine.

Table 2 to Paragraph (a)(1)—Oral Fluid, Initial Test Cutoff Levels for Drugs and Drug Metabolites

Drugs or drug metabolites Cutoff level 1 [nanograms (ng)/mL]

Marijuana (THC) 2 3 4

Cocaine/Benzoylecgonine 15

Opioids:

Codeine/Morphine 30

Hydrocodone/Hydromorphone 30

Oxycodone/Oxymorphone 30

6-acetylmorphine (6-AM) 4 3

Phencyclidine (PCP) 10

Amphetamines:

AMP/MAMP 4 50

MDMA/MDA 5 50

1 For grouped analytes (i.e., two or more analytes in the same drug class with the same initial test cutoff):

• Immunoassay: The test must be calibrated with one analyte from the group identified as the target analyte. The cross reactivity of the immunoassay to the other analyte(s) within the group must be 80 percent or greater; if not, separate immunoassays must be used for the analytes within the group.

• Alternative technology: Either one analyte or all analytes from the group must be used for calibration, depending on the technology. At least one analyte within the group must have a concentration equal to or greater than the initial test cutoff or, alternatively, the sum of the analytes present.

2 An immunoassay must be calibrated with the target analyte, delta-9-tetrahydrocannabinol (THC).

3 Alternate technology (THC and 6-AM): The confirmatory tests cutoff must be used for an alternate technology initial test that is specific for the target analyte (i.e., 2 ng/mL for THC, 2 ng/mL for 6-AM).

4 Amphetamine (AMP) and methamphetamine (MAMP).

5 Methylenedioxymethamphetamine (MDMA) and methylenedioxyamphetamine (MDA).

(2) HHS-certified laboratories shall conduct special analyses of specimens as follows:

(i) If initial validity testing indicates that a specimen is dilute, or if a specimen is collected under direct observation for any of the conditions specified in § 26.115(a)(1) through (3) or (a)(5), the laboratory shall compare the immunoassay responses of the specimen to the cutoff calibrator in each drug class tested;

(ii) If any immunoassay response is equal to or greater than 40 percent of the cutoff calibrator, the laboratory shall conduct confirmatory drug testing of the specimen to the LOQ for those drugs and/or drug metabolites; and

(iii) The laboratory shall report the numerical values obtained from this special analysis to the MRO.

(b) Confirmatory drug testing. (1) A specimen that is identified as positive on an initial drug test must be subject to confirmatory testing for the class(es) of drugs for which the specimen initially tested positive. The HHS-certified laboratory shall apply the confirmatory cutoff levels specified in this paragraph, except as permitted in paragraph (a)(2) of this section or the licensee or other entity has established more stringent cutoff levels.

Table 3 to Paragraph (b)(1)—Urine, Confirmatory Test Cutoff Levels for Drugs and Drug Metabolites

Drugs or drug metabolites Cutoff level (ng/mL)

Marijuana metabolite 1 15

Cocaine metabolite 2 100

Opioids:

Morphine 2,000

Codeine 2,000

Hydrocodone 100

Hydromorphone 100

Oxycodone 100

Oxymorphone 100

6-acetylmorphine (6-AM) 10

Phencyclidine (PCP) 25

Amphetamines:

Amphetamine 250

Methamphetamine 3 250

Methylenedioxymethamphetamine (MDMA) 250

Methylenedioxyamphetamine (MDA) 250

1 As delta-9-tetrahydrocannabinol-9-carboxylic acid (THCA).

2 As benzoylecgonine.

3 To be reported positive for methamphetamine, a specimen must also contain amphetamine at a concentration equal to or greater than 100 ng/mL.

Table 4 to Paragraph (b)(1)—Oral Fluid, Confirmatory Test Cutoff Levels for Drugs and Drug Metabolites

Drugs or drug metabolites Cutoff level [nanograms (ng)/mL]

Marijuana (THC) 2

Cocaine 8

Benzoylecgonine 8

Opioids:

Codeine 15

Morphine 15

Hydrocodone 15

Hydromorphone 15

Oxycodone 15

Oxymorphone 15

6-acetylmorphine (6-AM) 2

Phencyclidine (PCP) 10

Amphetamines:

Amphetamine 25

Methamphetamine 25

Methylenedioxymethamphetamine (MDMA) 25

Methylenedioxyamphetamine (MDA) 25

(2) Each confirmatory drug test must provide a quantitative result. When the concentration of a drug or metabolite exceeds the linear range of the standard curve, the laboratory may record the result as “exceeds the linear range of the test” or as “equal to or greater than <insert the value for the upper limit of the linear range>,” or may dilute an aliquot of the specimen to obtain an accurate quantitative result when the concentration is above the upper limit of the linear range.