10 CFR 429.24: Pool heaters.

Read at publisher ↗
Where this section sits in the code
  1. Title 10—Energy
  2. CHAPTER II—DEPARTMENT OF ENERGY
  3. SUBCHAPTER D—ENERGY CONSERVATION
  4. PART 429—CERTIFICATION, COMPLIANCE, AND ENFORCEMENT FOR CONSUMER PRODUCTS AND COMMERCIAL AND INDUSTRIAL EQUIPMENT
  5. Subpart B—Certification

(a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to pool heaters; and

(2) For each basic model of pool heater, a sample of sufficient size shall be randomly selected and tested to ensure that any represented value of the thermal efficiency or other measure of energy consumption of a basic model for which consumers would favor higher values shall be less than or equal to the lower of:

(i) The mean of the sample, where:

Or,

(ii) The lower 97 1/2 percent confidence limit (LCL) of the true mean divided by 0.95, where:

(b) Certification reports. (1) The requirements of § 429.12 are applicable to pool heaters; and

(2) Pursuant to § 429.12(b)(13), a certification report shall include the following public product-specific information: The thermal efficiency in percent (%) and the input capacity in British thermal units per hour (Btu/h).