(a) Scope. This section provides test procedures, pursuant to the Energy Policy and Conservation Act (EPCA), as amended, which must be followed for measuring the combustion efficiency and/or thermal efficiency of a gas- or oil-fired commercial packaged boiler.

(b) Testing and Calculations. Determine the thermal efficiency or combustion efficiency of commercial packaged boilers by conducting the appropriate test procedure(s) indicated in Table 1 of this section.

Table 1—Test Requirements for Commercial Packaged Boiler Equipment Classes

Equipment category Subcategory Certified rated input Btu/h Standards efficiency metric (§ 431.87) Test procedure (corresponding to standards efficiency metric required by § 431.87)

Hot Water Gas-fired ≥300,000 and ≤2,500,000 Thermal Efficiency Appendix A, Section 2.

Hot Water Gas-fired >2,500,000 Combustion Efficiency Appendix A, Section 3.

Hot Water Oil-fired ≥300,000 and ≤2,500,000 Thermal Efficiency Appendix A, Section 2.

Hot Water Oil-fired >2,500,000 Combustion Efficiency Appendix A, Section 3.

Steam Gas-fired (all*) ≥300,000 and ≤2,500,000 Thermal Efficiency Appendix A, Section 2.

Steam Gas-fired (all*) >2,500,000 and ≤5,000,000 Thermal Efficiency Appendix A, Section 2.

>5,000,000 Thermal Efficiency Appendix A, Section 2. OR Appendix A, Section 3 with Section 2.4.3.2.

Steam Oil-fired ≥300,000 and ≤2,500,000 Thermal Efficiency Appendix A, Section 2.

Steam Oil-fired >2,500,000 and ≤5,000,000 Thermal Efficiency Appendix A, Section 2.

>5,000,000 Thermal Efficiency Appendix A, Section 2. OR Appendix A, Section 3. with Section 2.4.3.2.

* Equipment classes for commercial packaged boilers as of July 22, 2009 (74 FR 36355) distinguish between gas-fired natural draft and all other gas-fired (except natural draft).

(c) Field Tests. The field test provisions of appendix A may be used only to test a unit of commercial packaged boiler with rated input greater than 5,000,000 Btu/h.