14 CFR 25.1731: Powerplant and APU fire detector system: EWIS.

Read at publisher ↗
Where this section sits in the code
  1. Title 14—Aeronautics and Space
  2. CHAPTER I—FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION
  3. SUBCHAPTER C—AIRCRAFT
  4. PART 25—AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES
  5. Subpart H—Electrical Wiring Interconnection Systems (EWIS)

(a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant.

(b) No EWIS component of any fire or overheat detector system for any fire zone may pass through another fire zone, unless:

(1) It is protected against the possibility of false warnings resulting from fires in zones through which it passes; or

(2) Each zone involved is simultaneously protected by the same detector and extinguishing system.

(c) EWIS that are part of each fire or overheat detector system in a fire zone must meet the requirements of § 25.1203.