16 CFR 1505.51: Hot surfaces.

Read at publisher ↗
Where this section sits in the code
  1. Title 16—Commercial Practices
  2. CHAPTER II—CONSUMER PRODUCT SAFETY COMMISSION
  3. SUBCHAPTER C—FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS
  4. PART 1505—REQUIREMENTS FOR ELECTRICALLY OPERATED TOYS OR OTHER ELECTRICALLY OPERATED ARTICLES INTENDED FOR USE BY CHILDREN
  5. Subpart B—Policies and Interpretations

(a) Test probe. Section 1505.6(g)(2) defines accessibility, for certain paragraphs, as the ability to reach a heated surface with a 1/4-inch-diameter rod 3 inches long. To test for accessibility using this test probe, it shall be inserted no more than 3 inches into any opening in the toy. Unless the probe contacts a surface within 3 inches of the plane of the toy's opening, that surface is not accessible.

(b) Accessibility of Type C and C-marked surfaces. Under § 1505.6(g)(2) (iii) and (iv), touching by casual contact or without employing the aid of a common household tool shall be determined by use of the accessibility test probe described in §§ 1505.6(g)(2) and 1505.51(a).