16 CFR 1505.8: Maximum acceptable material temperatures.

Read at publisher ↗
Where this section sits in the code
  1. Title 16—Commercial Practices
  2. CHAPTER II—CONSUMER PRODUCT SAFETY COMMISSION
  3. SUBCHAPTER C—FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS
  4. PART 1505—REQUIREMENTS FOR ELECTRICALLY OPERATED TOYS OR OTHER ELECTRICALLY OPERATED ARTICLES INTENDED FOR USE BY CHILDREN
  5. Subpart A—Regulations

The maximum acceptable material temperatures for electrically operated toys shall be as follows (Classes 105, 130, A, and B are from “Motors and Generators,” Standard MG-1-1967 1 published by the National Electrical Manufacturers Association):

Material Degrees C. Degrees F.

Capacitors (1) (1)

Class 105 insulation on windings or relays, solenoids, etc.:

Thermocouple method 2 90 194

Resistance method 110 230

Class 130 insulation system 110 230

Insulation:

Varnished-cloth insulation 85 185

Fiber used as electrical insulation 90 194

Class A Class B Class A Class B

Insulation on coil windings of a.c. motors (not including universal motors) and on vibrator coils:

In open motors and on vibrator coils—thermocouple or resistance method 2 100 120 212 248

In totally enclosed motors—thermocouple or resistance method 2 105 125 221 257

Insulation on coil windings of d.c. motors and of universal motors:

In open motors:

Thermocouple method 2 90 110 194 230

Resistance method 100 120 212 248

In totally enclosed motors:

Thermocouple method 2 95 115 203 239

Resistance method 105 125 221 257

Phenolic composition 3 150 302

Rubber- or thermoplastic-insulated wires and cords 3 60 140

Sealing compound (4) (5)

Supporting surface while the toy is operating normally 90 194

Wood and other similar combustible material 90 194

1 If the capacitor has no marked temperature limit, the maximum acceptable temperature will be assumed to be 65 °C. (149 °F.) for an electrolytic type and 90 °C. (194 °F.) for other than an electrolytic type.

2 The temperature indicated refers to the hottest spot on the outside surface of the coil measured by the thermocouple method.

3 The limitations on rubber- and thermoplastic-insulated wires and cords and on phenolic composition do not apply if the insulation or the phenolic has been investigated and found to have special heat-resistant properties, or if the insulation meets the thermal requirements.

4 40 less than melting point.

5 104 less than melting point.