29 CFR 1926.1409: Power line safety (over 350 kV).
Where this section sits in the code
- Title 29—Labor
- Subtitle B—Regulations Relating to Labor
- CHAPTER XVII—OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR
- PART 1926—SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION
- Subpart CC—Cranes and Derricks in Construction
The requirements of §§ 1926.1407 and 1926.1408 apply to power lines over 350 kV except:
(a) For power lines at or below 1000 kV, wherever the distance “20 feet” is specified, the distance “50 feet” must be substituted; and
(b) For power lines over 1000 kV, the minimum clearance distance must be established by the utility owner/operator or registered professional engineer who is a qualified person with respect to electrical power transmission and distribution.
Collected 2026-08-27T02:25:20Z. Source file · JSON