30 CFR 18.24: Electrical clearances.

Read at publisher ↗
Where this section sits in the code
  1. Title 30—Mineral Resources
  2. CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR
  3. SUBCHAPTER B—TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS
  4. PART 18—ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES
  5. Subpart B—Construction and Design Requirements

Minimum clearances between uninsulated electrical conductor surfaces, or between uninsulated conductor surfaces and grounded metal surfaces, within the enclosure shall be as follows:

Minimum Clearances Between Uninsulated Surfaces

Phase-to-Phase Voltage (rms) Clearances (inches)

Phase-to-Phase Phase-to-Ground or Control Circuit

0 to 250 0.25 0.25

251 to 600 0.28 0.25

601 to 1000 0.61 0.25

1001 to 2400 1.4 0.6

2401 to 4160 3.0 1.4