GroundRules
← Search the law
Federal regulations · Through 2026-08-25 · Newer source version available

30 CFR 56.6402: Deenergized circuits near detonators.

Read at publisher ↗
Where this section sits in the code
  1. Title 30—Mineral Resources
  2. CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR
  3. SUBCHAPTER K—METAL AND NONMETAL MINE SAFETY AND HEALTH
  4. PART 56—SAFETY AND HEALTH STANDARDS—SURFACE METAL AND NONMETAL MINES
  5. Subpart E—Explosives

Electrical distribution circuits within 50 feet of electric detonators at the blast site shall be deenergized. Such circuits need not be deenergized between 25 to 50 feet of the electric detonators if stray current tests, conducted as frequently as necessary, indicate a maximum stray current of less than 0.05 amperes through a 1-ohm resistor as measured at the blast site.

Collected 2026-08-27T02:25:24Z. Source file · JSON

Browse this collection