30 CFR 75.384: Longwall and shortwall travelways.
Where this section sits in the code
- Title 30—Mineral Resources
- CHAPTER I—MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR
- SUBCHAPTER O—COAL MINE SAFETY AND HEALTH
- PART 75—MANDATORY SAFETY STANDARDS—UNDERGROUND COAL MINES
- Subpart D—Ventilation
(a) If longwall or shortwall mining systems are used and the two designated escapeways required by § 75.380 are located on the headgate side of the longwall or shortwall, a travelway shall be provided on the tailgate side of that longwall or shortwall. The travelway shall be located to follow the most direct and safe practical route to a designated escapeway.
(b) The route of travel shall be clearly marked.
(c) When a roof fall or other blockage occurs that prevents travel in the travelway—
(1) Work shall cease on the longwall or shortwall face;
(2) Miners shall be withdrawn from face areas to a safe area outby the section loading point; and
(3) MSHA shall be notified.
(d) Work may resume on the longwall or shortwall face after the procedures set out in §§ 75.215 and 75.222 are implemented.
Collected 2026-08-27T02:25:24Z. Source file · JSON